Toshiba RAS-18UFHP-E3 Service Manual page 55

Air-conditioner under ceiling / console type
Table of Contents

Advertisement

RAS-18UFPX3-T2 / 18UAX3-T2
Power source
50 Hz, 220 V Single phase
Maximum running
16A
current
Plug socket &
fuse rating
2
4 mm
(H07RN-F or 245 IEC 66) or 3.5 mm
Power cord
(AWG-12)
CAUTION
Wrong wiring connection may cause some
electrical parts burn out.
Be sure to comply with local codes on running
the wire from indoor unit to outdoor unit (size of
wire and wiring method etc.)
Every wire must be connected firmly.
NOTE :Connection cable
Wire type : More than 1.5 mm
IEC66) or 1.3 mm
2
(AWG-16)
8-6. How to Set Remote Control Selector
RAS-24UFPX3-T / 24UAX3-T
18A
When two indoor units are installed in seperated
rooms, there is no need to change the selector switch.
20A
<Remote control selector switch>
2
• When two indoor units are installed in the same
• The remote control signal is not recived when the
1. Set the remote control selector switch with the
1) Turn the circuit breaker of the main power switch off
2
(H07RN-F or 245
2) Remove the Air inlet grille. (Refer to page 47, 8-4-2)
3) Select the terminal of selector switch from [A
– 53 –
FILE NO. SVM-04032
Switch
room or the adjacent two rooms, they may be
controlled simultaneously with a single remote
control. To prevent this, set either unit and its remote
control to B setting. (Both units are set to A setting
before shipment.)
indoor unit setting is different from the remote
control one.
indoor unit.
before setting the selector switch.
Fig. 8-6-1
position] to [B position].
Fig. 8-6-2