Toshiba RAS-18UFHP-E3 Service Manual page 25

Air-conditioner under ceiling / console type
Table of Contents

Advertisement

5-3. RAS-18UFP-AR3 / RAS-18UA-AR3
0.39m
(Connecting pipe)
∅12.70 mm
0.39m
(Flexible pipe)
∅12.70 mm
O.D.:12.70 mm
Packed valve
(∅12.70)
Accumulator
Compressor
2JS350D5DA02
50Hz
Standard
Cooling
High temperature
Low temperature
Note : Measure the heat exchanger temperature at the center of U-bend. (By means of TC sensor.)
Multi blade fan
P
Condenser
Propeller fan
Outdoor unit
Standard
pressure P
(MPaG)
0.4
0.6
0.3
T
Indoor unit
Evaporator
Capillary tube
∅0.8x900S
Surface temp. of heat
exchanger interchanging
pipe T (°C)
10.0
13.0
2.0
– 24 –
FILE NO. SVM-04032
0.49m
(Connecting pipe)
∅6.35 mm
O.D.:6.35 mm
Packed valve
(∅6.35)
Capillary tube
∅2.0x1000S
Dryer
Refrigerant
R-22 1.17 kg
Mark (
) means check points of Gas Leak
Ambient temp.
conditions DB/WB
Fan speed
(indoor)
Indoor
High
27/19
High
32/23
Low
21/15
(°C)
Outdoor
35/24
52/31
21/15

Advertisement

Table of Contents
loading

Table of Contents