Toshiba RAS-18UFHP-E3 Service Manual page 24

Air-conditioner under ceiling / console type
Table of Contents

Advertisement

5-2. RAS-18UFP-E3 / RAS-18UA-E3
RAS-18UFPX3 / RAS-18UAX3
0.39m
(Connecting pipe)
∅12.70 mm
0.39m
(Flexible pipe)
∅12.70 mm
O.D.:12.70 mm
Packed valve
(∅12.70)
2JS350D5DA02
Compressor
50Hz
Standard
Cooling
High temperature
Low temperature
Note : Measure the heat exchanger temperature at the center of U-bend. (By means of TC sensor.)
Indoor unit
Evaporator
Multi blade fan
P
Condenser
Propeller fan
Outdoor unit
Standard
pressure P
(MPaG)
0.4
0.5
0.3
T
Refrigerant
R-22 1.05 kg
Mark (
Surface temp. of heat
exchanger interchanging
pipe T (°C)
10.0
13.0
2.0
– 23 –
FILE NO. SVM-04032
0.49m
(Connecting pipe)
∅6.35 mm
O.D.:6.35 mm
Packed valve
(∅6.35)
Capillary tube
∅2.0x700S
Dryer
) means check points of Gas Leak
Ambient temp.
conditions DB/WB
Fan speed
(°C)
(indoor)
Indoor
High
27/19
High
32/23
Low
21/15
Outdoor
35/24
43/26
21/15

Advertisement

Table of Contents
loading