4-3. Outdoor Unit (RAS-18UAX3, RAS-18UA-E3)
No.
Parts name
1
Compressor
2
Fan motor (for outdoor)
Running capacitor
3
(for fan motor)
Running capacitor
4
(for compressor)
5
Magnetic contactor
4-4. Outdoor Unit (RAS-18UA-AR3)
No.
Parts name
1
Compressor
2
Fan motor (for outdoor)
Running capacitor
3
(for fan motor)
Running capacitor
4
(for compressor)
5
Magnetic contactor
4-5. Outdoor Unit (RAS-18UAX3-T2)
No.
Parts name
1
Compressor
2
Fan motor (for outdoor)
Running capacitor
3
(for fan motor)
Running capacitor
4
(for compressor)
5
Magnetic contactor
Type
Output (Rated) 1500 W, 2 poles, 1 phase, 220 – 240 V, 50 Hz
2JS350D5DA02
Winding resistance (Ω)
(at 20°C)
Output (Rated) 42 W, 6 poles, 1 phase, 220 – 240 V, 50 Hz
HF-240-42B-1
Winding resistance (Ω)
(at 20°C)
451205KQ
AC 450 V, 2µF
371456JCR
AC 370 V, 45µF
CLK-26J
220 – 240 V, 50 Hz
Type
Output (Rated) 1500 W, 2 poles, 1 phase, 220 – 240 V, 50 Hz
2JS350D5DA02
Winding resistance (Ω)
(at 20°C)
Output (Rated) 65 W, 6 poles, 1 phase, 220 – 240 V, 50 Hz
KFG6-71SB5P-T4
Winding resistance (Ω)
(at 20°C)
451205KQ
AC 450 V, 2µF
SK42CMP45U1-S
AC 420 V, 45µF
CLK-35J
220 – 240 V, 50 Hz
Type
Output (Rated) 1500 W, 2 poles, 1 phase, 220 – 240 V, 50 Hz
PH210T2-4L7
Winding resistance (Ω)
(at 20°C)
Output (Rated) 65 W, 6 poles, 1 phase, 220 – 240 V, 50 Hz
KFG6-71SB5P-T
Winding resistance (Ω)
(at 20°C)
451355KQ
AC 450 V, 3.5µF
371356JCR
AC 420 V, 35µF
CLK-26J
220 – 240 V, 50 Hz
– 19 –
FILE NO. SVM-04032
Specifications
C-R
0.981
Red-Black
White-Black
176.2
Specifications
C-R
0.981
Red-Black
White-Black
68.15
Specifications
C-R
1.07
Red-Black
White-Black
64.4
C-S
2.845
290.5
C-S
2.845
170.50
C-S
2.20
127.4

Advertisement