Ignition Cycles; Running In Minimum Or Maximum; Running In The Comfort Level Mode; Clear Space - Pelpro PP60 Owner's Manual

Hide thumbs Also See for PP60:
Table of Contents

Advertisement

J. Ignition Cycles
1. At the beginning of each ignition cycle, it is normal to see
some smoke in the fi rebox. The smoke will stop once
the fi re starts.
2. The convection blower will automatically turn on after
your appliance has been burning for approximately 10
minutes.
This blower transfers heat from your appliance into the
room, and will continue to run even after the unit has
shutdown. It will turn off after the exhaust temperature
has cooled.
3. Occasionally the appliance may run out of fuel and shut
itself down. When this happens the empty hopper alarm
will be triggered.
K. Running in Minimum or Maximum
When the dial control is set to run on the LO or HI setting,
the appliance will continue to run without regard to the
actual temperature in the room. The appliance will shut off
only if the dial control is set to a different setting or there is
an error such as an empty hopper.
When running on LO or HI it is important to follow the daily
cleaning activities especially cleaning the fi repot. Failure
to do so will reduce the performance of the appliance.
L. Running in the Comfort Level Mode
When the dial control is set to run in the automatic mode
the unit will adjust the actual burn rate based on the
difference between the room temperature as sensed by
the probe located in the rear of the unit and the desired
comfort level as set on the dial control.
The comfort level range is from 65 degrees Fahrenheit to
82 degrees Fahrenheit.
Once the desired comfort level is achieved the appliance
will automatically shut down and turn off. When the
temperature in the room drops 3 degrees below the
desired comfort level, the appliance will automatically
restart.
3
2
1
LO
OFF
www.pelprostoves.com
5
4
6
7
8
9
10
HI
7083-171H • February 23, 2015
M. Clear Space
Mantel:
Avoid placing candles and other heat-sensitive
objects on mantel or hearth. Heat may damage these objects.
NOTICE: Clearances may only be reduced by means ap-
proved by the regulatory authority having jurisdiction.
WARNING
Fire Risk
HOT WHILE IN OPERATION. KEEP
CHILDREN, CLOTHING, AND FURNITURE
AWAY. CONTACT MAY CAUSE SKIN BURNS.
WARNING
Fire Risk
Keep combustible materials, gasoline and other
fl ammable vapors and liquids clear of appliance.
• Do NOT store fl ammable materials in the
appliance's vicinity.
• Do NOT use gasoline, lantern fuel, kerosene, charcoal
lighter fl uid or similar liquids or gels to start or "freshen
up" a fi re in this heater.
Keep all such liquids well away from the heater while it is
in use as combustible materials may ignite.
N. Trim Adjustment
The trim adjustment is the small dial located below the
main dial control.
If the fi re is too large, lazy or producing black soot, rotate
the dial counterclockwise one level at a time and allow 15
minutes for stabilization before making another adjustment.
If your fi re is too small and sometimes goes out when there
are pellets in the hopper, rotate the dial clockwise one
level at a time and allow 15 minutes for stabilization before
making another adjustment.
11

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents