Low Image Density; Foggy Background - Minolta Di151 Service Manual

Hide thumbs Also See for Di151:
Table of Contents

Advertisement

FrameMaker Ver.5.5E(PC) Di151 TROUBLESHOOTING
00.03.10
(3)

Low image density

Section
Step
1
Toner has run out.
2
The image transfer current ter-
minal is dirty.
3
The Image Transfer Roller is
deteriorated.
4
The developing bias terminal
Engine
is dirty.
5
The Regulator Blade terminal
is dirty.
6
Image density is still low even
after the I/C has been
changed.
1
Wiring between the Scanner
and Control Board is con-
IR
nected.
(4)

Foggy background

Section
Step
1
Extraneous light has entered
the copier.
1
PC Drum is contaminated with
foreign matter.
2
Drum charge voltage terminal
is dirty.
3
Regulator Blade terminal is
Engine
dirty.
4
Seal bias terminal is dirty.
5
Foggy background still occurs
even after the I/C has been
changed.
1
Mirrors and lens are dirty.
2
Exposure Lamp is dirty.
IR
3
Wiring between the Scanner
and Control Board is con-
nected.
Check
Result
YES Change I/C.
YES Clean.
YES Change.
YES Clean.
YES Clean.
YES Change High Voltage Unit.
YES Change Scanner.
NO
Check
Result
YES Protect copier from extrane-
YES Clean.
YES Clean.
YES Clean.
YES Clean.
YES Change High Voltage Unit.
YES Clean.
YES Clean.
YES Change Scanner.
NO
T-21
Action
Change PH Unit.
Change Master Board.
Change Control Board.
Connect.
Action
ous light.
Change PH Unit.
Change Master Board.
Change Control Board.
Connect.

Advertisement

Table of Contents
loading

Table of Contents