Needle Stop Position (3230 Only) - ELNA 3210 Service Manual

Hide thumbs Also See for 3210:
Table of Contents

Advertisement

Elna International Corps. SA
The height of the needle point should be 10-14 mm above the needle plate when the machine stops.
If not, correct it as follows:
Adjustment procedure:
1. Remove the base (See page 5.)
2. Turn the power switch ON and press the needle up/down button twice to bring the needle bar to
the highest position.
3. If the needle point is higher than 14 mm: Loosen the setscrew C and turn the lower shaft
shielding plate E in the direction of A.
4. If the needle point is lower than 10 mm: Loosen the setscrew C and turn the lower shaft shielding
plate E in the direction of B.
5. Tighten the setscrew C.
6. Press the needle up/down button twice and check the needle stop position.
7. Attach the base.
Needle Bar Stop Position (Model 3230 only)