Needle Stop Position (Applicable To Model 6125Qc Only) - ELNA 6125QC Service Manual

Table of Contents

Advertisement

Needle Bar Stop Position (applicable to Model 6125QC only)
The height of the needle point should be 10-14 mm above the needle plate when the machine stops. If not,
correct it as follows:
Adjustment procedure:
1. Remove the base (See page 7.)
2. Turn the power switch ON and press the needle up/down button twice to bring the needle bar to the
highest position.
3. If the needle point is higher than 14 mm: Loosen the setscrew and turn the lower shaft shielding plate in
the direction of (A).
4. If the needle point is lower than 10 mm: Loosen the setscrew and turn the lower shaft shielding plate in
the direction of (B).
5. Tighten the setscrew.
6. Press the needle up/down button twice and check the needle stop position. Attach the base.
Needle plate
Mechanical Adjustment
Setscrew
10-14 mm
(A)
(B)
23
Setscrew
Lower shaft
Lower shaft shield plate

Advertisement