3.14 Setup for STICK (MMA) Welding

A. Connect the Electrode Holder lead to the positive welding terminal (+). If in doubt, consult the electrode
manufacturer. Welding current flows from the Power Source via heavy duty bayonet type terminals. It is
essential, however, that the male plug is inserted and turned securely to achieve a sound electrical connection.
B. Connect the work lead to the negative welding terminal (-). If in doubt, consult the electrode manufacturer.
Welding current flows from the power source via heavy duty bayonet type terminals. It is essential, however,
that the male plug is inserted and turned securely to achieve a sound electrical connection.
C. Select STICK mode with the process selection control (refer to Section 3.08.7 for further information)
Before connecting the work clamp to the work and inserting the electrode in the electrode holder
make sure the mains power supply is switched off.
Remove any packaging material prior to use. Do not block the air vents at the front or rear of the
Welding Power Source.
Loose welding terminal connections can cause overheating and result in the male plug being fused
in the bayonet terminal.
Positive Welding
Terminal (+)
INSTALLATION, OPERATION AND SETUP
!
WARNING
CAUTION
CAUTION
A
MODE
I
1
PULSE
I
High Current
s
w
Base
Current
Width
Hot
I
Up
z
Start
Slope
t1
Initial
Frequency
Current
PURGE
Pre
Flow
AC FREQUENCY
BACK
202
P O R T A B L E
W E L D I N G
S Y S T E M
8
Electrode Holder
Figure 3-11: Setup for Manual Arc Welding.
3-18
202 AC/DC INVERTER
V
V
SEC
%
Hz
PROCESS
LIFT TIG
I
2
HF TIG
I
e
f
Down
Low
Slope
STICK
Current
Crater
t2
Current
Post
TRIGGER
Flow
2T
WAVE BALANCE
ARC FORCE
4T
FORWARD
A-11407
Work Lead
Negative Welding
Terminal (-)
Manual 0-5239

Advertisement

Table of Contents
loading

Table of Contents