Message List; Error Messages - Yamaha HTR-6063 Owner's Manual

Av receiver yamaha htr-6063
Hide thumbs Also See for HTR-6063:
Table of Contents

Advertisement

Message list

NOTE
If the following messages appear, resolve the problems that have
occurred and carry out the measurement process again.
■ When a warning message is displayed before
measurement
Connect MIC!
The YPAO microphone is
not connected.
Unplug HP!
The headphones are
connected.
Memory Guard!
The settings of this unit
are protected.

■ Error messages

E-1:
No Front SP
E-2:
No Sur. SP
E-3:
No F.PRNS SP
Connect the YPAO
microphone to the YPAO
MIC jack on the front
E-4:
panel.
SBR→SBL
Remove the headphones.
Set "Memory Guard" in
E-5:
the Setup menu to "Off"
Noisy
(☞p.
87).
E-6:
Check Sur.
The unit was not able to
Check that the left and
find the front channel.
right front speakers are
connected correctly.
The unit was only able to
Check that the left and
find one of side of the
right surround speakers
surround channels.
are connected correctly.
The unit was only able to
Check that the left and
find one of side of the
right presence speakers
presence channels.
are connected correctly.
Only one surround back
When only one surround
speaker is connected and
back speaker is
only the right side
connected, connect to the
surround back channel
left side (SINGLE)
sound is detected.
terminal.
The noise is too loud,
Measure again in quiet
preventing accurate
surroundings. Turn off any
measurements from
devices in the room that
being taken.
may be emitting noise, or
place them further away
from the YPAO
microphone.
When this message is
displayed, selecting
"PROCEED" will allow
you to continue measuring.
However, we recommend
resolving the problem and
measuring again, as
continuing measurement
without doing so will not
give accurate results.
Even though surround
When using surround back
left and right speakers are
speakers, connection of the
not connected, only the
surround left/right
surround back speakers
speakers is necessary.
are connected.
CONNECTIONS
Setting up the speaker parameters automatically (YPAO)
E-7:
The YPAO microphone
No MIC
has been removed.
E-8:
The YPAO microphone
No Signal
could not distinguish a
test tone.
E-9:
You have carried out an
User Cancel
operation that has
cancelled the measuring
process.
E-10:
An internal error has
Internal Error
occurred.
While measuring, take
care not to touch the
YPAO microphone.
Check that the YPAO
microphone has been
installed correctly.
Check that each speaker
has been connected and
installed correctly.
The YPAO microphone
or the YPAO MIC jack
may be broken. Inquire at
the retailer where you
purchased this unit, or the
nearest Yamaha service
center.
Carry out the measuring
process again. Do not
operate this unit by, for
example, adjusting the
volume.
Carry out the measuring
process again. Contact a
Yamaha service center if
"E-10" is displayed
again.
38
En

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rx-v667

Table of Contents