29.0 View downloaded data file - continued
Header information
At the top of each data file the following information is displayed:
• Version of FloCom
used to download the file;
+
• Time and date the data was downloaded to the PC;
• Device type; ie AgriFlo, FloPro or HydroMace 3000;
• Serial number of the electronics module;
• Version of firmware installed in the electronics module;
• Time and date of the clock in the electronics module;
• Battery status and charge (voltage) of the electronics module;
• Number of channels being recorded;
• The names of each channel being recorded;
• The units of measure used for each channel being recorded;
• 'Points' refers to the number of data lines in the downloaded file;
• 'Interval' refers to the time in seconds between each time stamp (logging
interval).
Status messages
Status messages are defined by the use of an asterisk (*) immediately
following a time stamp. For example, in the download on the previous
page the following message appears which tells the user the date and time
the unit was started. The name of the channel which caused the event is
included in the message text.
NOte: refer to the table over page for a full listing of status messages
Time stamped data
At each time stamp the date, time and recorded channel values are shown. In
the example below the date and time are followed by the recorded values for
each of the five configured channels which are Depth, Flow Rate, Flow Total,
Pulse Total and Pump Status..
End of file
The end of the data file is always delineated by a 'Download End' followed by
the date and time.
86
SeCtion b SoFtware Manual
Status message table
Status message
Unit started
Unit stopped
No external power
External power restored
Low Battery
Battery normal
Flat battery condition
Battery was flat
Sensor error
Device reset #0
TOD clock error
Pulse event
Status change
RetuRn to toC
RetuRn to toC
Description
HM 3000 was started
HM 3000 was stopped
No external power is detected. If a solar panel is used this
will occur at sunset.
External power is detected. If a solar panel is used this
will occur at sunrise.
Time at which battery voltage fell below 11.5V
Time at which battery voltage exceeded 11.5V
Battery voltage at download time is less than 10V
Battery was less than 10V
MACE I/O module not detected
Power up reset occurred
Error reading Time-of-day clock
A pulse from a pulse event channel has occured
The value on a status event channel has changed
MaCe HydRoMaCe 3000 Product Manual