21.3.10 Edit a "Binary" channel type
Channel name
Decimal places
Units text
Invert input
Channel name
This is the name given to the channel by the user when setup.
NOte: this name will also show on the hM 3000 LCD screen if the Display
channel check box is ticked
Decimal places
This field is greyed out as the "Binary" channel cannot have decimal places
configured.
Display channel
If this check box is ticked then this channel will be displayed on the HM 3000
LCD.
Log channel
If this check box is ticked then this channel will be logged in the data file.
Units text
This sets the units on the logged value. This is a text field and is user defined.
In this example the "Binary" channel is being used to monitor the on/off
condition of a pump. In the data the word "Pump" will be logged whenever
the pump is on.
Invert input
If this check box is ticked then the value will be inverted before it is logged.
70
SeCtion b SoFtware Manual
22.0 Configure outputs
From the "HM 3000
settings" dialogue box,
Display channel
click "Configure outputs"
Log channel
and the "Configure
outputs" dialogue box will
appear.
22.1 adding outputs
From the "Configure outputs" dialogue box click "Add"
and the "Select output type" dialogue box will appear.
22.1.1 Adding a 4-20mA output
1. From the "Select output type" dialogue box highlight
"4..20mA out" and click "Continue". The "Select output"
dialogue box will appear.
2. Select the "4..20mA output #X" that you wish to
use and click "Continue". The "Select source channel"
dialogue box will appear.
RetuRn to toC
RetuRn to toC
MaCe HydRoMaCe 3000 Product Manual
71