(8) [Video Record]
Specify the video record action. If [Enable] is
selected, video will be transmitted to the destination
selected in [Video Record Action] (p. 54) when a
volume detection event occurs.
(9) [E-mail Notification]
Select the e-mail notification operation to be
performed. If [Enable] is selected, e-mail notification
is performed when a volume detection event occurs.
To use this function, the [E-mail Notification] sub-
menu must also be set from the [Upload] menu
(p. 51).
(10)[External Device Output for ON Event]
Select whether external device output is active or
inactive upon an ON event. Select [Disable] to disable
external device output.
(11)[External Device Output for OFF Event]
Select whether external device output is active or
inactive upon an OFF event. Select [Disable] to
disable external device output.
Important
• For notes on use of volume detection, see "Safety
Precautions" in "Precautions for Use of Built-In Camera
Functions and Included Software" (p. 7).
• When Admin Viewer/VB Viewer has camera control
privileges, those camera control privileges are released if the
camera is moved to a preset position, specified in the
[Preset] settings (VB-S30D/VB-S31D only), by a volume
detection event.
External Device Output
(1) [Operation Mode]
Select the normal (inactive) circuit condition.
When [Normally Open] is selected, the output
terminals remain in the open state during normal
operation, and the terminals close upon an active
event and open upon an inactive event.
When [Normally Close] is selected, the output
terminals remain in the closed state during normal
operation, and the terminals open upon an active
event and close upon an inactive event.
(2) [Active Output Format]
Select [Pulse] or [Continuous] for the external device
output format.
(3) [Pulse Output Time (sec)]
Enter the pulse output time in the range of 1 to 120
(sec.). This setting is available when [Active Output
Format] is [Pulse].
[Event] Setting Video Record, Volume Detection, External Device Output/Input and Timer
Important
When [Active Output Format] is set to [Pulse] and a timer is
used, a single contact output is controlled when the timer starts.
Note
[Normally Open] means that the contacts are normally in the
open state (that the circuit is non-conductive), and [Normally
Close] means that the contacts are normally in the closed state
(that the circuit is conductive).
Normally Open
Active Event
Inactive Event
Normally Close
Inactive Event
Active Event
External Device Input
(1) [External Device Input Event]
Set external device input events to [Disable] or
[Enable].
(2) [Operation Mode]
Select the circuit condition of the connected external
device.
When [Normally Open] is selected, an active event
occurs when the terminals of the external device
close, and an inactive event occurs when the
terminals open.
When [Normally Close] is selected, an active event
occurs when the terminals of the external device
open, and an inactive event occurs when the
terminals close.
(3) [Active Event Operation]
Select the operation to be performed upon an active
event. If [Enable] is selected, (5) [Preset], (6) [Video
Record] and (7) [E-mail Notification] will be executed
according to their settings upon an active event.
(4) [Inactive Event Operation]
Select the operation to be performed upon an inactive
event. If [Enable] is selected, (5) [Preset], (6) [Video
Record] and (7) [E-mail Notification] will be executed
according to their settings upon an inactive event.
4
1 (Terminals close)
0 (Terminals open)
1 (Terminals close)