Logic Level Frequency; Non-Contact Ef-Detection; Record Mode; Diode Tester - Brymen TBM811 User Manual

Table of Contents

Advertisement

Logic Level Frequency ( Hz) & Duty
Cycle (D%)
@ DCmV
Function
5.00Hz ~
Frequency
1.000MHz
Duty Cycle 0.00% ~ 100.0% 3d/kHz+2d
Sensitivity: 2.5Vp (Square wave) for 3V &
1)
5V Logic Family
Specified Frequency: 5Hz ~ 10kHz
2)

Non-Contact EF-Detection

Typical Voltage
20V (tolerance:10V~36V)
55V (tolerance: 23V ~ 83V)
110V (tolerance: 59V ~ 165V)
220V (tolerance: 124V ~ 330V)
440V (tolerance: > 250V)
Indication: Bar graph segments & audible
beep tones proportional to the
field strength
Detection Frequency: 50/60Hz
Detection Antenna: Top end of the meter
Probe-Contact EF-Detection:
For more precise indication of live wires,
such as distinguishing between live and
ground connections, use the Red (+) test
probe for direct contact measurements.
Crest mode (Instantaneous Peak Hold)
Accuracy: Specified accuracy adds 250
digits for changes > 1.0 ms in duration

Record mode

Accuracy: Specified accuracy adds 10 digits
for changes > 100 ms in duration
Range
Accuracy
0.04%+4d
Bar Graph
Indication

Diode Tester

RANGE
1)
2.000V
Test Current (Typically): 0.4mA
Open Circuit Voltage: < 3.5 VDC
2)
Temperature
RANGE
-50
C to 1000
o
-58
F to 1832
o
Type-K thermocouple range & accuracy not
included
-
--
---
----
-----
Accuracy
1.0%+1d
Accuracy
C
0.3%+2
o
F
0.3%+5
o
22
C
o
F
o

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Tbm812Tbm811xexTbm829Tbm812xexTbm525