Error Code Description
1701-xx
Hard drive format test failed.
1702-xx
Hard drive read test failed.
1703-xx
Hard drive write/read/compare test failed.
1704-xx
Hard drive random seek test failed.
1705-xx
Hard drive controller test failed.
1706-xx
Hard drive ready test failed.
1707-xx
Hard drive recalibration test failed.
1708-xx
Hard drive format bad track test failed.
1709-xx
Hard drive reset controller test failed.
1710-xx
Hard drive park head test failed.
1715-xx
Hard drive head select test failed.
1716-xx
Hard drive conditional format test failed.
1717-xx
Hard drive ECC* test failed.
1719-xx
Hard drive power mode test failed.
1724-xx
Network preparation test failed.
1736-xx
Drive monitoring test failed.
*ECC = Error Correction Code
2-14
Troubleshooting
Table 2-10
Hard Drive Test Error Codes
Recommended Action
The following steps apply to error codes 1701-xx
through 1736-xx:
1. Run Compaq Utilities and verify drive type.
2. Verify that all secondary drives have secondary
drive capability.
3. Replace the hard drive and retest.
4. Replace the system board and retest.