The microphone input level may also be set using the setup
menu. For details on the setup menu, contact a Sony
service or sales representative.
WF REMOTE (waveform monitor remote) connector
The MIC REMOTE connector can be used as a WF
REMOTE (waveform monitor remote) connector using
the setup menu.
Used to attach to the appropriate connector on a recall-type
waveform monitor
when operating the waveform monitor display using an
MSU-900 series Master Setup Unit or an RCP-700 series
Remote Control Panel.
When using a recall-type monitor, preset a display mode
on the waveform monitor, and then recall the mode
externally.
For details on these operations, refer to the Master Setup
Unit or Remote Control Panel manuals.
l RCP/CNU connector (8-pin)
Used to connect to an MSU-900 series Master Setup Unit,
CNU-700 Camera Command Network Unit, or RCP-700
series Remote Control Panel via a CCA-5 Connection
Cable.
Control signals are sent and received via this connector.
When using an RCP-700 series unit, power is also
supplied.
m WF MODE (waveform monitor mode) connector
(4-pin)
Connect to the appropriate connector on a waveform
monitor when monitoring a signal in sequential mode.
A sequence signal will be output when the SEQ button on
the RCP-700 series Remote Control Panel is pressed,
allowing simultaneous monitoring of the R, G, and B
signals in sequential mode.
When both the RCP and MSU are in use, this connector
functions as the output connector for RCP control.
For details on these operations, refer to the Master Setup
Unit or Remote Control Panel manuals.
n TRUNK A connector (12-pin)
Used to connect to the CCU connector on a video camera
via an RS-232C or RS-422A interface.
Communication with up to two channels is available.
o AC IN (AC power input) connector
Use the specified AC power cord to connect to an AC
power supply.
The AC power cord can be secured to this unit, using the
plug holder (optional).
52
Locations and Functions of Parts
HKCU1001 SD Encoder Unit
(optional)
Note
To reduce the risk of electric shock, fire or injury, do not
open the cabinet. To adjust the internal settings, refer to
qualified service personnel.
The HKCU1001 consists of an EN-A front board and a
VDA-A rear board.
When these boards are installed in the front and rear
expansion slots of the unit, the unit outputs SD composite
signals, waveform monitor output signals, and picture
monitor output signals through the VDA-A board.
For details on installation, contact a Sony service or sales
representative.

EN-A Board

EN-A
NTSC
1 SD signal format indicators
PAL
SC PHASE
ADV
2 SC PHASE switch
DELAY
a SD signal format indicators
Either of these indicators lights, corresponding to the SD
signal format.
b SC PHASE (subcarrier phase) switch
Used to adjust the SC phase with respect to the reference
signal (black burst).
This switch will return its original position when you
release it. Press and hold the switch towards ADV to
advance the phase or towards DELAY for delay.