Fireplace Placement Requirements

Fireplace must be installed on a level surface capable of supporting the fireplace and vent
Fireplace must be placed directly on wood or non-combustible surface (not on linoleum or carpet)
Fireplace should be located out of traffic and away from furniture and draperies.
Fireplace must be placed so the gaps below and above the glass frame do not become blocked.
Fireplace may be placed in a bedroom.

Clearances

(a) Clearance to Side of Fireplace: 3" (76mm). Do not place insulation in this space.
(b) When installed, walls in front of the fireplace must be a minimum 3" (76mm) to the side of the
fireplace.
(c) Clearance to Cover Box (Rear Edge): 0" (0mm)
a
b

Raised Fireplaces

The fireplace (and hearth, if desired) may be placed on a platform designed to support the fireplace
and vent.
HINT: We typically have displayed this fireplace on a 24" to 36" raised platform. Keep in mind that the
firebox opening (base of the flames) is 12" above the base. Desired position may vary depending
upon room size, typical viewing angle, and aesthetic intent.
© Travis Industries
Installation
(for qualified installers only)
c
4140717
11
100-01351