Optional Remote Wall Switch; Optional Remote Control Installation; Optional Wall Thermostat; Final Check - Regency F33-NG1 Owners & Installation

F33 freestanding
Table of Contents

Advertisement

INSTALLATION

OPTIONAL REMOTE WALL SWITCH

1)
Run wire through the opening in the rear of the unit. Be
careful not to damage wire.
Note: We recommend a maximum of 4.5m of wire but if
you wish to go with a longer run use the Thermostat
Wire Table.
2)
Connect wire to wall switch and install into receptacle box.
Caution:
Do not wire millivolt wall switch for gas appliance to
a 240V power supply.
OPTIONAL REMOTE CONTROL
INSTALLATION
Use the Optional Regency Remote Control Kit approved for this
unit. Use of other systems may void your warranty.
The remote control kit comes with a hand held transmitter, a
receiver and a wall mounting plate.
1)
Choose a convenient location on the wall to install the
receiver and the receptacle box (protection from extreme
heat is very important). Run wires from the fireplace to that
location. Use Thermostat Wire Table.
2)
Connect the two wires to the gas valve. See diagram below.
3)
Install a 9V alkaline battery in both receiver and the transmit-
ter. Install the receiver and cover in the wall. The remote
control is now ready for operation.
12

OPTIONAL WALL THERMOSTAT

INSTALLATION
A wall thermostat may be installed if desired.
Note: Preferable if the thermostat is installed on an interi-
or wall.
Use a CSA, UCL or UL approved millivolt thermostat, 250-750
millivolt rated. A non-anticipator type thermostat must be used.
Thermostat Wire Table
Recommended Maximum Lead Length
(Two-Wire) When Using Wall
Thermostat (CP-2 System)
Wire Size
14 GA.
16 GA.
18 GA.
20 GA.
22 GA.

FINAL CHECK

Before leaving this unit with the customer, the installer must
ensure that the appliance is firing correctly. This includes:
1)
Checking the operating pressure (see data label)
2)
If required, adjusting the primary air to ensure that the flame
does not carbon. First allow the unit to burn for 15 min. to
stabilize.
3)
Check for proper draft.
CAUTION: Any alteration to the product that causes soot-
ing or carboning that results in damage to the unit is not the
responsibility of the manufacturer and will not be covered by
the warranty.
Regency F33-1 Freestanding Gas Stove
Max. Length
15.24 m
9.75 m
6.10 m
3.66 m
2.71 m

Advertisement

Table of Contents
loading

This manual is also suitable for:

F33-lpg1

Table of Contents