SAFETY SCREEN
INSTALLATION / REMOVAL
1. Install slotted brackets (found in the manual pack)
to the back of the door with 2 screws on each
side as shown below.
2. To install the safety screen, hook the tabs on the
safety screen into the slotted bracket on either
side of the glass door.
3. To remove the safety screen, lift up slightly and
pull forward.
DOOR HANDLE
Attach spring handle by rotating counter clockwise
onto rod. Ensure that the spring fits into the entire
length of the rod.
DO NOT TRY TO TURN
DOOR HANDLE!
IT IS NOT DESIGNED
TO BE MOVED.
REMOTE CONTROL
INSTALLATION
Use the Regency
Remote Control Kit supplied
®
with this unit. Use of other systems may void your
warranty.
The remote control kit comes with a hand held
transmitter, a receiver and a wall mounting plate.
CAUTION
Do not wire millivolt remote control
wires to the
120V AC wires
1. Install 3 AAA alkaline batteries in transmitter
and 4 AA alkaline batteries in the receiver.
Install the receiver and its cover in the wall.
Switch the remote receiver to "remote" mode.
The remote control is now ready for operation.
Regency
installation
OPTIONAL WALL THERMOSTAT
A wall thermostat may be installed if desired.
Connect the wires as per the wiring Diagrams.
Note that the wires are connected to the "TH" on
the gas valve. Use table below to determine the
maximum wire length:
Note: Preferable if the thermostat is installed
on an interior wall.
Regency
®
thermostat but any 250-750 millivolt rated non-
anticipator type thermostat that is CSA, ULC or
UL approved may be used.
Do not connect the millivolt
wall thermostat wires
Thermostat Wire Table
Recommended Maximum Lead Length
(Two-Wire) When Using Wall
Thermostat (CP-2 System)
Wire Size
14 GA.
16 GA.
18 GA.
20 GA.
22 GA.
FINAL CHECK
Before leaving this unit with the customer, the
installer must ensure that the appliance is firing
correctly. This includes:
1. Clocking the appliance to ensure the correct
firing rate (rate noted on label) at 15 minutes.
2. If required, adjusting the primary air to ensure
that the flame does not carbon. First allow the
unit to burn for 15 min. to stabilize.
3. Check for proper draft.
Any alteration to the product that causes
sooting or carboning that results in damage
to the exterior facia is not the responsibility of
the manufacturer.
CLASSIC™ C34-10 Direct Vent Freestanding Gas Stove
®
offers an optional programmable
CAUTION
to the 120V wires.
Max. Length
50 Ft.
32 Ft.
20 Ft.
12 Ft.
9 Ft.
CAUTION
|
31
|
31