Operating Instructions; Lighting Procedure; Shutdown Procedure - Regency F33-NG1 Owners & Installation

F33 freestanding
Table of Contents

Advertisement

OPERATING INSTRUCTIONS

1)
The FIRST FIRE in your stove is part of the paint curing
process. To ensure that the paint is properly cured, it is
recommended that you burn your fireplace for at least four
(4) hours the first time you use it with the fan on. When first
operated, the unit will release an odour caused by the curing
of the paint and the burning off of any oils remaining from
manufacturing. Smoke detectors in the house may go off at
this time. Open a few windows to ventilate the room for a
couple of hours. The glass panel may require cleaning.
DO NOT ATTEMPT TO CLEAN THE GLASS WHILE IT
IS STILL HOT!
Note:
When the glass is cold and the appliance is lit, it may
cause condensation and fog the glass. This condensa-
tion is normal and will disappear in a few minutes as the
glass heats up.
DO NOT BURN THE APPLIANCE WITHOUT THE GLASS
FRONT IN PLACE.
2)
Read and understand these instructions before operating
this appliance.
3)
Check to see that all wiring is correct and enclosed to
prevent possible shock.
4)
Check to ensure there are no gas leaks.
5)
Make sure the glass in the door frame is properly positioned.
Never operate the appliance with the glass removed.
6)
Verify that the fluing is unobstructed.
7)
Verify log placement. If the pilot cannot be seen when lighting
the unit - the logs have been incorrectly positioned.
8)
The unit should never be turned off, and on again without a
minimum of a 60 second wait for purging.
WARNING
DO NOT SPRAY AEROSOLS IN THE
VICINITY OF THIS APPLIANCE WHILE
IT IS IN OPERATION
Regency F33-1 Freestanding Gas Stove
OPERATING INSTRUCTIONS

LIGHTING PROCEDURE

IMPORTANT:
Gas cock knob cannot be turned from
"PILOT" to "OFF" unless it is partially depressed.
1)
Turn burner OFF using "ON/OFF" switch.
2)
Turn gas control knob so indicator points to "OFF" position
and allow 5 minutes for any gas in the combustion chamber
to escape.
3)
Turn gas control knob counterclockwise so indicator points
to the "PILOT" position. Depress the gas control knob fully.
Depress the igniter button several times until the pilot lights.
After approximately one minute, release the gas control
knob. The pilot flame should continue to burn. If the pilot does
not remain lit, repeat operation allowing a longer period
before releasing gas control knob.
4)
When the pilot stays lit, turn the gas knob further counter-
clockwise to the "ON" position.
5)
Use the ON/OFF switch, wall switch, thermostat or remote
control to turn on the unit.
6)
Rotate the flame height regulator (Hi/Lo) to adjust the flame
height higher or lower.

SHUTDOWN PROCEDURE

1)
Use the ON/OFF switch, wall switch, thermostat or remote
control to turn off the burner.
2)
Push in the PILOT knob slightly and turn clockwise to off. Do
not force.
3)
Turn off all electric power to the appliance if service is to be
performed.
13

Advertisement

Table of Contents
loading

This manual is also suitable for:

F33-lpg1

Table of Contents