Regency FG39-NG1 Owners & Installation Manual

Regency FG39-NG1 Owners & Installation Manual

Freestanding gas stove
Hide thumbs Also See for FG39-NG1:
Table of Contents

Advertisement

Quick Links

Owners &
Installation
LISTINGS AND CODE APPROVALS
These gas appliances have been tested in
accordance with AS4553, NZS 5262 and
have been certifi ed by the Australian Gas
Association for installation and operation
as described in these Installation and
Operating Instructions.
Your unit should be serviced annually
by an authorised service person.
Freestanding Gas Stove
PLEASE KEEP THESE INSTRUCTIONS
FOR FUTURE REFERENCE
WARNING:
Improper installation, adjustment, altera-
tion, service or maintenance can cause
injury or property damage. Refer to this
manual. For assistance or additional in-
formation consult an authorized installer,
service agency or the gas supplier.
FOR YOUR SAFETY
Do not store or use gasoline or other fl am-
mable vapours and liquids in the vicinity of
this or any other appliance.
Installation and service must be performed
by an authorized installer, service agency or
the gas supplier.
918-646b
Models: FG39-NG1
FG39-LPG1
FOR YOUR SAFETY
What to do if you smell gas:
Do not try to light any appli-
ance
Do not touch any electri-
cal switch: do not use any
phone in your building.
Immediately call your gas
supplier from a neighbour's
phone. Follow the gas sup-
plier's instructions.
If you cannot reach your
gas supplier, call the fi re
department.
03/11/10

Advertisement

Table of Contents
loading

Summary of Contents for Regency FG39-NG1

  • Page 1 Owners & Installation Freestanding Gas Stove Models: FG39-NG1 FG39-LPG1 PLEASE KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE WARNING: FOR YOUR SAFETY Improper installation, adjustment, altera- What to do if you smell gas: tion, service or maintenance can cause Do not try to light any appli- injury or property damage.
  • Page 2 To the New Owner: Congratulations! You are the owner of a state-of-the-art Regency Room Sealed Gas Stove by FPI Fireplace Products International Ltd. The Regency Gas Series of hand crafted appliances has been designed to provide you with all the warmth and charm of a woodstove. The models FG39-NG and FG39-LPG of this series has been approved by AGA.
  • Page 3 UNIT SPECIFICATIONS Regency FG39-1 FireGenie Freestanding Gas Stove...
  • Page 4: Table Of Contents

    Summary of Controls ..........25 Installation Checklist ..........7 Pilot Adjustment ............25 Clearances to Combustibles........7 Normal Operating Sounds of Gas Appliances ..25 Locating Your Regency Gas Stove ......7 Copy of Lighting Plate Instructions ......26 Combustion and Ventilation Air.........7 Louver Installation ............8 Flueing Introduction ..........8 Maintenance Installation Precautions ..........8...
  • Page 5: Safety Label

    SAFETY LABEL NOTE: Regency units are constantly being This is a copy of the label that accompanies each improved. Check the label on the unit and if REGENCY FG39 Freestanding Gas Stove. We there is a difference, the label on the unit is the have printed a copy of the contents here for your correct one.
  • Page 6: Installation

    OF HIGH SURFACE TEMPERA- SPECIFICATIONS TURES, ESPECIALLY THE FIRE- INFORMATION PLACE GLASS, AND SHOULD Fuels: FG39-NG1 is approved for use with STAY AWAY TO AVOID BURNS 1) The appliance shall be installed in accord- OR CLOTHING IGNITION. ance with the manufacturer's installation instructions,local gas fi...
  • Page 7: Installation Checklist

    1) Clocking the appliance to ensure the correct from outside the building through the outer fl ue. fi ring rate (rate noted on label) after burning Extra provision for combustion air inside the appliance for 15 minutes. room is not required. Regency FG39-1 FireGenie Freestanding Gas Stove...
  • Page 8: Louver Installation

    Simpson Dura-Flue Room Sealed System side stove panel using 2 screws per the FG39-NG1, and FG39-LPG1. The warranty Model DV-GS fl uing systems, in combination side. will be voided and serious fi re, health or other...
  • Page 9: Exterior Flue Termination Locations

    (IV) A fl ue terminal of this type shall not be located under a roofed area unless the roofed area is fully open on at least two sides and a free fl ow of air at the appliance is achieved. Regency FG39-1 FireGenie Freestanding Gas Stove...
  • Page 10: Flueing Arrangements - Horizontal

    To set the Flue restriction as indicated in the diagram, simply loosen the screws and push the fl ue restrictor plate to the correct position. Tighten the screws. Flue Restrictor setting at Flue Restrictor setting at 31 Mj/h 40 Mj/h Regency FG39-1 FireGenie Freestanding Gas Stove...
  • Page 11: Dv Stove Horizontal Flue Kit

    Be sure to check fl ue termination area after snow falls, and clear to prevent accidental blockage of fl uing system. When using snow blowers, make sure snow is not di- rected towards fl ue termination area. Regency FG39-1 FireGenie Freestanding Gas Stove...
  • Page 12 13) Install the spring spacers onto the pipe Mill-Pac. sections. All outer joints may be sealed with 14) Secure the 4" (102mm) dia. fl ex liner with high temperature silicone. adapter onto the stove collar. Put a bead of Regency FG39-1 FireGenie Freestanding Gas Stove...
  • Page 13: Dura-Flue Termination Kit

    1 Astro Cap COMPONENTS You will require the following components with your new Regency Room Sealed Freestand- ing Gas Stove. Please review your product to make sure you have everything you need. In the efl ue that you are missing any part, contact your dealer.
  • Page 14: Dura-Flue Horizontal Installation

    See diagram 6. onto the male ends of adjacent pipes and fi ttings, by orienting the four pipe indentations so they match and slide in Diagram 2 to the four entry slots on the male ends Regency FG39-1 FireGenie Freestanding Gas Stove...
  • Page 15: Dura-Flue Vertical Termination Installation

    This as shown in diagram 9 to avoid cutting load allows for small adjustments. bearing members. Regency FG39-1 FireGenie Freestanding Gas Stove...
  • Page 16: Offset Chart

    Use a minimum of four #8 x 1/2" (13mm) screws per bracket. In some cases these brackets may need to be trimmed Regency FG39-1 FireGenie Freestanding Gas Stove...
  • Page 17: Gas Connection

    10 mm Open Caution: Carbon will be produced if the air shutter is closed too much. Note: Any damage due to carboning result- ing from improperly setting the aera- tion controls is NOT covered under warranty. Regency FG39-1 FireGenie Freestanding Gas Stove...
  • Page 18: Conversion From Ng To Lpg

    7) Remove the pilot orifi ce with the allen key. 10) Adjust the burner areation setting to fully open and install the burner. 11) Remove the pedestal back cover by remov- ing the 4 Phillips screws. Burner Orifi ce Regency FG39-1 FireGenie Freestanding Gas Stove...
  • Page 19 23) Reverse step 19. 24) Check operation of fan and fl ame control. 25) Check for proper fl ame appearance and glow on logs. Installer Notice: These instructions must be left with the appliance. Regency FG39-1 FireGenie Freestanding Gas Stove...
  • Page 20: Conversion To Lower Btu

    12) Check inlet and outlet pressures. 13) Check operation of fl ame control. Check for proper fl ame appearance and glow on logs. Embers. Embers Position the Log Bracket Restrictor between the Rear Log Bracket and the burner. Regency FG39-1 FireGenie Freestanding Gas Stove...
  • Page 21 6) Place Front Left Log C)02-44 onto the 2 front pins as shown. 10) Place the notch in Center Log F)02-47 over B)02-56 E)02-45 Log E)02-45 and across the cutout on Log C)02-44 A)02-65. C)02-44 F)02-47 A)02-65 E)02-45 Notch Cutout Regency FG39-1 FireGenie Freestanding Gas Stove...
  • Page 22: Front Door Installation

    REMOTE CONTROL results in damage to the exterior facia is not the responsibility of the Diagram 1 Use the Regency Remote Control Kit approved manufacturer. for this unit. Use of other systems may void your warranty. The remote control kit comes with a hand held transmitter and a wall mounting plate.
  • Page 23: Wiring Diagram

    This appliance is equipped with a three pronged (grounding) plug for your protection against shock hazard and should be plugged directly into a properly grounded three-prong receptacle. Do not cut or remove the grounding prong from this plug. Regency FG39-1 FireGenie Freestanding Gas Stove...
  • Page 24: Operating Instructions

    DO NOT ATTEMPT TO CLEAN THE GLASS WHILE IT IS STILL HOT! DO NOT BURN THE APPLIANCE WITH- OUT THE GLASS FRONT IN PLACE. Regency FG39-1 FireGenie Freestanding Gas Stove...
  • Page 25: Summary Of Controls

    NOTE: If you have an incorrect fl ame pat- Increase - If the unit is switched on, pressing tern, contact your Regency dealer for further and releasing the fl ame plus (+) button once will Blower: instructions.
  • Page 26: Copy Of Lighting Plate Instructions

    Turn off all electric power to the unit if service is to be performed. DO NOT REMOVE THIS INSTRUCTION PLATE 918-332a WARNING: DO NOT SPRAY AEROSOLS IN THE VICINITY OF THIS APPLIANCE WHILE IN OPERATION. Regency FG39-1 FireGenie Freestanding Gas Stove...
  • Page 27: Maintenance

    BE PLACED ON OR NEAR THE heat resistant paint (not with wall paint). LATCH ADJUSTMENT APPLIANCE. Regency uses StoveBright Paint - Metallic Black #6309. The door latch may require adjustment as the DO NOT USE THIS APPLIANCE door gasket material compresses after a few fi res...
  • Page 28: Glass Replacement

    Your Regency heater is supplied with high tem- wall of the fi rebox. NOTE: the unit MUST NOT provide access to the fan.
  • Page 29: Removing Valve Tray

    See diagram below. 6) Disconnect the manual switch cable and reset cables. Manual Switch Reset Cables Cable Regency FG39-1 FireGenie Freestanding Gas Stove...
  • Page 30: Parts List

     910-935 Manual Control Switch *Note: The Control Box Cable wires for the FG38 come separately: 910-502, 910-505, 910-506, 910-507, 910-509 The Control Box Cable wires for the IG35 come separately: 910-530, 910-504, 910-528 Regency FG39-1 FireGenie Freestanding Gas Stove...
  • Page 31: Main Assembly

    Pedestal Back 19) 730-530 Side Panel Door Assy (Right Side) 20) 730-525 Side Panel Door Assy (Left Side) 21) 560-031 Side Panel Door Hinge 23) 904-258 Side Panel Door Magnet 24) 948-255 Door Latch Regency FG39-1 FireGenie Freestanding Gas Stove...
  • Page 32: Burner And Log Assembly

    630-008 Gasket - Burner Tray/ Firebox 730-935 Log Set Rear Log Left Top Log Center Log Middle Right Log Middle Left Log Front Right Log Front Left Log *Not available as a replacement part. Regency FG39-1 FireGenie Freestanding Gas Stove...
  • Page 33: Door Assembly

    Black Wrap Door - Complete 101) 846-570 Door Gasket Kit 105) Ceramic Paper 107) 936-243 Glass Gasket 111) Door Frame Fibre Paper 208) 940-325/P Wrap Glass *Not available as a replacement part. WRAP DOOR Regency FG39-1 FireGenie Freestanding Gas Stove...
  • Page 34 NOTES ___________________________________________________ ___________________________________________________ ___________________________________________________ ___________________________________________________ ___________________________________________________ ___________________________________________________ ___________________________________________________ ___________________________________________________ ___________________________________________________ ___________________________________________________ ___________________________________________________ ___________________________________________________ ___________________________________________________ ___________________________________________________ ___________________________________________________ ___________________________________________________ ___________________________________________________ ___________________________________________________ ___________________________________________________ ___________________________________________________ ___________________________________________________ ___________________________________________________ ___________________________________________________ ___________________________________________________ Regency FG39-1 FireGenie Freestanding Gas Stove...
  • Page 35: Warranty

    Regency codes. Also, all service work must be carried out by an Fireplace Products.
  • Page 36 © Copyright 2010 FPI Fireplace Products International Ltd. All rights reserved. Printed in Canada...

This manual is also suitable for:

Fg39-lpg1

Table of Contents