Regency F33-NG3 Owners & Installation

Freestanding gas stove
Hide thumbs Also See for F33-NG3:

Advertisement

Owners &
Installation
LISTINGS AND CODE APPROVALS
These gas appliances have been tested in
accordance with AS4553, NZS 5262 and
have been certified by the Australian Gas
Association for installation and operation
as described in these Installation and
Operating Instructions.
Your unit should be serviced annually
by an authorised service person.
F33 Freestanding Gas Stove
PLEASE KEEP THESE INSTRUCTIONS
FOR FUTURE REFERENCE
WARNING:
Improper installation, adjustment, altera-
tion, service or maintenance can cause
injury or property damage. Refer to this
manual. For assistance or additional in-
formation consult an authorized installer,
service agency or the gas supplier.
FOR YOUR SAFETY
Do not store or use gasoline or other flam-
mable vapours and liquids in the vicinity of
this or any other appliance.
Installation and service must be performed
by an authorized installer, service agency or
the gas supplier.
918-532e
Models:
F33-NG3
F33-LPG3
FOR YOUR SAFETY
What to do if you smell gas:
Do not try to light any appli-
ance
Do not touch any electri-
cal switch: do not use any
phone in your building.
Immediately call your gas
supplier from a neighbour's
phone. Follow the gas sup-
plier's instructions.
If you cannot reach your
gas supplier, call the fire
department.
04/08/15

Advertisement

Table of Contents
loading

Summary of Contents for Regency F33-NG3

  • Page 1 Owners & Installation F33 Freestanding Gas Stove Models: F33-NG3 F33-LPG3 PLEASE KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE WARNING: FOR YOUR SAFETY Improper installation, adjustment, altera- What to do if you smell gas: tion, service or maintenance can cause Do not try to light any appli- injury or property damage.
  • Page 2 Gas Series of hand crafted appliances has been designed to provide you with all the ® warmth and charm of a woodstove, at the flick of a switch. The models F33-NG3 and F33-LPG3 have been approved by the Australian Gas Association for both safety and efficiency. As it also bears our own mark, it promises to provide you with economy, comfort and security for many trouble free years to follow.
  • Page 3: Table Of Contents

    Optional Remote Control Installation ......12 Optional Wall Thermostat Installation ....... 12 PARTS LIST Thermostat Wire Table ..........12 Final Check...............12 Main Assembly ............21 Burner & Log Assembly ..........22 Pedestal & Leg Assembly .........23 WARRANTY Warranty ..............26 Regency F33-3 Freestanding Gas Stove ®...
  • Page 4: Data Badge

    DATA BADGE This is a copy of the label that accompanies each Regency F33-3 DATA BADGE NOTE: Regency units are constantly being improved. ® ® Freestanding Gas Stove. We have printed a copy of the contents here Check the label on the unit and if there is a difference, the label on for your review.
  • Page 5: Installation

    1) Clocking the appliance to ensure the correct firing rate (rate noted on label) after burning appliance for 15 minutes. 9) Under no circumstances should this appliance be modified. Parts that have to be removed for servicing should be replaced prior to operating this appliance. Regency F33-3 Freestanding Gas Stove ®...
  • Page 6: Pedestal Assembly

    Use washers which are supplied with the pedestal as shown in diagram. Reinstall bolts. CLEARANCES TO COMBUSTIBLES 3) Push the Regency logo into the two holes in the front bottom left ® corner of the pedestal cover plate.
  • Page 7: Leg And Bottom Shield Assembly

    10) Connect the orange wire from the spill switch to the Burner ON/OFF switch. 11) Re-connect the fan harness plug. 12) Secure the power cord with the supplied grommet at the back of the Bottom Shield or Pedestal. Regency F33-3 Freestanding Gas Stove ®...
  • Page 8: Wiring

    610m. we recommend that a minimum flue height of 3.6m is used. chimney/flue in accordance with installation codes. For your safety this heater is equipped with a flue safety switch. This thermally actuated switch is located within the draft hood and will detect Regency F33-3 Freestanding Gas Stove ®...
  • Page 9: Gas Connection

    1) Make sure the valve is in the "OFF" position. 2) Loosen the "IN" and/or "OUT" pressure tap(s), turning counter- clockwise with a 1/8" wide flat screwdriver. 3) Attach manometer to "IN" and/or "OUT" pressure tap(s) using a 5/16" ID hose. Regency F33-3 Freestanding Gas Stove ®...
  • Page 10: Test For Flue Spillage

    6) Place the cross logs on top of the larger logs aligning the holes on the underside of the cross log with the log pins in the larger logs. See diagrams 1 & 2. Carefully push the cross logs onto the pins. Diagram 1 Regency F33-3 Freestanding Gas Stove ®...
  • Page 11: Safety Latch

    8) If the flame hesitates at any point, check the area of hesitation and see if there is an ember or rock wool blocking a burner port or ports. If so, move the obstruction and then check the flame flow again. Regency F33-3 Freestanding Gas Stove ®...
  • Page 12: Optional Remote Wall Switch

    OPTIONAL REMOTE CONTROL (Two-Wire) When Using Wall Thermostat (CP-2 System) INSTALLATION Wire Size Max. Length Use the Optional Regency Remote Control Kit approved for this unit. ® 14 GA. 15.24 m Use of other systems may void your warranty. 16 GA.
  • Page 13: Operating Instructions

    2) Push in the PILOT knob slightly and turn clockwise to off. Do not force. 3) Turn off all electric power to the appliance if service is to be per- formed. Regency F33-3 Freestanding Gas Stove ®...
  • Page 14: Copy Of The Lighting Plate Instructions

    You may shut off the pilot during prolonged non use periods to conserve fuel. DO NOT REMOVE THIS INSTRUCTION PLATE 908-649c Part #: 908-649c Regency F33-3 Freestanding Gas Stove ® Colours: Black on Grey, except for parts in RED Size: 100%...
  • Page 15: Maintenance

    Never use an abrasive cleaner. The glass should be cleaned with a gas fireplace glass cleaner (when it starts to cloud up). 3) The heater is finished in a heat resistant paint and should only be refinished with heat resistant paint. Regency uses Stove Brite ®...
  • Page 16: General Flue Maintenance

    The pilot light generates enough heat to burn someone. If for any reason a log should need replacement, use only Regency ® replacement logs. The position of these logs must be as shown in the diagram under Log Installation.
  • Page 17: Aeration Adjustment

    Note: If you have an incorrect flame pattern, contact your 1) Shut off gas supply. Regency dealer for further instructions. ® 2) If optional fan is installed, disconnect power source to stove. 3) Remove access panel.
  • Page 18: Installing Valve Assembly

    1) To install a new valve assembly, reverse instructions for removing valve. See assembly steps 1-11. 2) Check for leaks and manifold pressure. See Gas Pressure Test instruc- tions. 3) To reinstall valve, reverse instructions for removing valve assembly, steps 12-18. Regency F33-3 Freestanding Gas Stove ®...
  • Page 19: Fan Replacement

    3. NOTE: Make sure the fan is supported as it may fall when the 4 screws are loosened. Wiring Diagram Diagram 3 View from back of stove Placement of Decal Strain relief “Warning 240 Volts grommet Turn Off Power” Regency F33-3 Freestanding Gas Stove ®...
  • Page 20: Troubleshooting The Gas Control System

    Thermopile and/or thermo- grounding against gas appliance and/or gas valve. couple may be grounding • Follow same steps for thermocouple. out. Note: For service technicians only. See the Regency Troubleshooting Guide for more detailed information. ® (Troubleshooting Regency Gas Products) ®...
  • Page 21: Parts List

    Hinge Cap - Gold Plated (2/set) Screw #10 - 24 x 3/4" Pan Head Washer 1/4" split lock Screw #10 - 24 x 1/2 Pan Head 471-031 Door Retainer Clip 948-101 Spring Handle - Large Regency F33-3 Freestanding Gas Stove ®...
  • Page 22: Burner & Log Assembly

    3/8 x 12" Black Mall Nipple 948-294 Burner - NG 948-279 Burner - LPG *Not available as a replacement part. Complete Burner Tray Assy-SIT-NG Complete Burner Tray Assy-SIT-LPG 490-023 Front Log Deflector - NG/LPG Regency F33-3 Freestanding Gas Stove ®...
  • Page 23: Pedestal & Leg Assembly

    PEDESTAL & LEG ASSEMBLY Part # Description Part # Description Pedestal Assembly Bottom Shield & Leg Option 490-926 Complete Pedestal 100) 948-216 Logo Plate - Regency ® 100) 948-216 Logo Plate - Regency ® 102) 904-257 Magnetic Catch - Large 102) 904-257...
  • Page 24 NOTES Regency F33-3 Freestanding Gas Stove ®...
  • Page 25 NOTES Regency F33-3 Freestanding Gas Stove ®...
  • Page 26: Warranty

    Regency shall in no event be liable for any special, indirect consequential damages of any nature whatsoever which are in excess of the original purchase price of the product. Any alteration to the unit which causes sooting or carboning that results in damage to the exterior facia is not the responsibility of Regency Fireplace Products.
  • Page 27 NOTE: PLEASE RETAIN YOUR INVOICE AS PROOF OF PURCHASE FOR WARRANTY VERIFICATION INCORRECT INSTALLATION OR GAS PRESSURE SETTINGS ARE NOT COVERED BY WARRANTY A SERVICE OR CALLOUT FEE WILL BE CHARGED IN THESE CIRCUMSTANCES. Regency F33-3 Freestanding Gas Stove ®...
  • Page 28 Register your Regency warranty online ® www.regency-fire.com.au Reasons to register your product online today! • View and modify a list of all your registered products. • Request automatic email notification of new product updates. • Stay informed about the current promotions, events, and special offers on related products.

This manual is also suitable for:

F33-lpg3