Regency F2500 Manual

Regency F2500 Manual

Wood medium stove
Hide thumbs Also See for F2500:

Advertisement

Quick Links

Model
Cordwood BTU's
Emissions (grams/hr) EPA Certified
Efficiency (EPA HHV)*
Efficiency (EPA LHV)
Flue Size
US Biomass Tax Rebate Eligible
Maximum Log Size
Firebox Size
*US Biomass Tax Rebate eligibility is based on the HHV value being
greater than or equal to 75%.
UNIT DIMENSIONS
24"
610mm
Images for OUTSIDE AIR DIMENSIONS
OUTSIDE AIR DIMENSIONS
1
21
"
4
540mm
Rear
Front
F2500 Wood Medium Stove
F2500
78,000 BTU's
1 gram/hr
76%
81%
6" (152mm)
Yes
18" (457mm)
2.3 cu.ft.
24"
610mm
1
21
"
4
540mm
4-9/16" (115mm)
Images for OUTSIDE AIR DIMENSIONS
1
27
"
8
690mm
13
24
"
16
1
630mm
27
"
8
7
6
"
690mm
16
163mm
13
24
"
16
630mm
7
6
"
16
163mm
Rear
Front
Rear
4-9/16" (115mm)
6-13/16"(173mm)
F2500 Wood Stove |
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the F2500 and is the answer not in the manual?

Questions and answers

Diane Rae Lunde-Hansen
February 10, 2025

What product do you recommend for cleaning the top of the stove?

2 comments:
Diane Rae Lunde-Hansen
February 10, 2025

what product can I use to clean the top of my wood stove

Mr. Anderson
February 11, 2025

The Regency F2500 stove manual recommends using 220 sandpaper to clean the thermostat probe. It also advises professional chimney cleaning using proper tools such as a correctly sized brush and a special vacuum cleaner designed for fine particles.

This answer is automatically generated

Summary of Contents for Regency F2500

  • Page 1 F2500 Wood Medium Stove Model F2500 Cordwood BTU’s 78,000 BTU’s Emissions (grams/hr) EPA Certified 1 gram/hr Efficiency (EPA HHV)* Efficiency (EPA LHV) Flue Size 6" (152mm) US Biomass Tax Rebate Eligible Maximum Log Size 18” (457mm) Firebox Size 2.3 cu.ft.
  • Page 2: Minimum Clearance To Combustible Materials

    From Corner From Flue Center-Line Medium F2500M with Airmate 15" (381mm) 7" (178mm) 5" (127mm) 27" (686mm) 13.5" (343mm) 17" (432mm) with Rear Deflector 15" (381mm) 9" (229mm) 5" (127mm) 27" (686mm) 15.5" (394mm) 17" (432mm) | F2500 Wood Stove...
  • Page 3: Floor Protection

    MINIMUM ALCOVE CLEARANCE AND CLEARANCE TO COMBUSTIBLE MATERIALS The Regency Freestanding models have been alcove approved and must be installed with a listed double wall connector to the ceiling level. Note: Minimum alcove ceiling height - 83" Maximum depth of alcove - 48"...
  • Page 4 27-5/16" (694mm) 33-11/16" (856mm) 59-7/16" (1510mm) 49-3/4" (1264mm) 25-7/8" (657mm) Residential Close Clearance (To be installed with required pipe components) Canada 33-11/16" (856mm) 57-15/16" (1472mm) 48-5/8" (1235mm) 24-13/16" (630mm) 33-11/16" (856mm) 55-15/16" (1421mm) 47-1/4" (1200mm) 23-7/16" (595mm) | F2500 Wood Stove...
  • Page 5 11. WARNING: DO NOT INSTALL IN A SLEEPING ROOM OF A MOBILE HOME. 12. Use silicone to create an effective vapour barrier at the location where the chimney or other component penetrates to the exterior of the structure. F2500 Wood Stove |...
  • Page 6 8. If you are using a horizontal connector, the chimney connector should be as high as possible while still maintaining the 18" (457mm) minimum distance from the horizontal connector to the ceiling. | F2500 Wood Stove...
  • Page 7: Masonry Chimney

    Maintain proper clearance to the structure as recommended by the manufacturer. The chimney must be the required height above the roof or other obstructions for safety and proper draft operation. The space heater is to be connected to a factory-built chimney conforming to CAN/ULC-S629, Standard for 650 C Factory-Built Chimneys. F2500 Wood Stove |...
  • Page 8: Combustible Wall Chimney Connector Pass-Throughs

    Cover opening with and support chimney section on both sides with 24 gage minimum sheet metal supports. See that the supports are fastened securely to wall surfaces on all sides. Make sure fasteners used to secure the metal chimney connector do not penetrate chimney flue liner. | F2500 Wood Stove...
  • Page 9: Recommended Heights For Woodstove Flue

    Example b) 1000' 18.72' 21.84' 2000' 19.44' 22.68' 5000' 21.60' 25.20' 8000' 23.76' 27.72' WARNING: CAUTION: The structural integrity of the mobile home DO NOT INSTALL IN SLEEPING floor, wall and ceiling/roof must be maintained. ROOM F2500 Wood Stove |...

This manual is also suitable for:

F2500-1

Table of Contents