Failed Devices; I 2 C Port (Enclosure Monitoring) - Infortrend EonStor U16U-G4010 Installation And Hardware Reference Manual

320mb/sec scsi-to-scsi raid subsystem
Table of Contents

Advertisement

Parameter
+3.3V
+5V
+12V
CPU Temperature
Board Temperature
Table 3-7: Default Threshold Values
The thresholds in Table 3-7 are the default threshold values. The user can change these
values. To see how to change these values please refer to the Generic Operation Manual
that came with your system.

3.6.2 Failed Devices

If any of the following devices fail the audible alarm will be triggered.
2
3.7. I
C Port (Enclosure Monitoring)
Figure 3-7: I 2 C Port
The component status of an expansion enclosure is reported through an I
This serial bus is connected to a RAID system over the enclosure's I
included I
I2C Port (Enclosure Monitoring)
RAID Controller Modules
Cooling Fan Modules
PSU Modules
BBU Modules
Hard Drives
2
C cable.
Upper Threshold
Lower Threshold
+3.6V
+2.9V
+5.5V
+4.5V
+13.2V
+10.8V
90ºC
0ºC
90ºC
0ºC
Chapter 3: Subsystem Monitoring
2
C serial bus.
2
C port using the
3-9

Advertisement

Table of Contents
loading

Table of Contents