1. STANDARD INSTALLATION
a.
Make sure all preparation steps are completed.
b.
Determine your ceiling height to see if you need an extension.
ii. Standard DC height = 15-3/4 (lower) + 17 (upper)
iii. Minimumheight (Standard duct cover only) =
iv. Maximum height (Standard duct cover only) = 3
v. (OPTIONAL) RA-76ExtDC Minimum height = 31-1/2
vi. (OPTIONAL) RA-76ExtDC Maximum height = 54-1/2
vii. Standard Installation = Hood + standard DC
viii. Long Installation = Hood + RA-76ExtDC
c.
Determine the location you want to install the range hood. (Fig. 2a)
d.
Prepare ceiling and locate wood support.
e.
Use stencil to guide the support frame installation.
f.
Mount the unit upper support frameto the ceiling.
g.
h.
Attach upper duct cover to the upper support frame using 4 screws.
i.
Insert lower support frame to the upper support frame.
j.
Adjust the lower support frame to your desired height. (Fig. 2b)
k.
Use a spirit level to ensure the balance of the support frame is true.
l.
Slide lower duct cover into the support frames and secure with screws.
m. Install ducting through the ceiling.
n.
Secure hood from the bottom by using the (8) screws provided. (Fig. 2c)
o.
Connect piping to the outlet of the hood.
p.
Installation is complete when hood is securely in place. (Fig. 2d)