Industrial PCs MCR5000
R
EMOVING THE RETAINING CLIP
2) The battery is kept in place with a plugged in retaining clip. The retaining clip can be
removed from the battery compartment by carefully lifting the external tabs by using a
flat-bladed tool (screw driver).
R
EPLACING THE BATTERY
3) Now the lithium battery can be removed. It must be replaced by the same battery type,
only. The type of battery to be used is:
Saft LS 14250 / 1/2AA 3.6V 1000mAh / Lithium battery
Please observe the correct polarity when replacing the battery.
Warning:
There is a risk of explosion if the battery is replaced with the wrong type or with
the wrong polarity. Adhere to the valid regulations for environmentally-friendly
disposal of batteries if the battery has reached the end of its life cycle.
A
SSEMBLY
© ads-tec GmbH • Heinrich-Hertz-Str. 1 • D-72622 Nürtingen
: