Error Code
Description
0096
SUBADDRESS/PASSWORD capability not match in polling Rx mode
009A
Can't detect any signal after sending CI signal
009D
Remote side hang up before V34 modem enter phase 2 state in V34 polling Rx
009E
Manual Tx over 15 minutes whin in phase C by non-ECM mode
00A0
Transmission was manually canceled on the machine.
00A1
There is a document jam.
00AE
Can't finished V8 procedure or detect V21 signal after CM signal within 30 sec
Modem can't enter into control channel after Tx side sending out RCP signal
00AF
for V34
Cannot finish V8 procedure or detect V21 signal after ANSam signal within
00B1
35sec
00B2
Can't detect phase 2 signal after our side sending CJ signal within 30 sec
00B3
Can't detect correct V21 or JM signal after sending CM signal
Can't detect correct phase 2 signal within 25 seconds after CM/JM signal
00B4
exchange
00B5
Can't detect phase 3 signal after phase 2 within 25 seconds
00B6
Can't detect phase 4 signal within 25 seconds after CM/JM exchange
00B8
Remote side disconnect after our side sending DCS signal in V34
00BA
Cannot received correct signal after our side sending DTC signal in V34
00BB
Every time our side received DIS signal after sending DTC in V34
00BC
Modem can't ready within 10 second after entering primary channel in V34
00BD
Can't detect correct V.21 or JM signal after detected FSK frequency
00BE
Remote side no document to be polled after V8 handshaking
00BF
Capability no match after V8 handshaking
At phase D, transmitting units out EOP 3times consecutively, but receive no
00C1
answer from receiving unit
00C2
Remote side disconnect after sending out CM signal
After sending MPS signal, the received is not one of MCF, RTN, PIP, PIN, RTP,
00C4
DCN
00C5
Received DCN signal after sending MPS signal
00C9
At phase D, sending MPS 3 times consecutively, but no answer from receiveing unit
00CA
After sending EOP signal, the received is not one of MCF, RTN, PIP, PIN, PRI-EOP, DCN
00CB
After sending EOP signal, the received is DCN signal
00CF
Received incorrect signal after sending DTC signal for V34 polling
00D0
Received ERR signal after sending EOR_NULL
00D1
Received incorrect response after sending PPS_EOP signal in V34
00D2
Received DCN after sending PPS_EOP signal
00D3
Received DCN after sending PPS_NULL signal
00D8
Can't detect correct phase 3 signal for polling within 25 seconds
00D9
Can't detect correct phase 3 signal after detect silence after phase 2
Can't detect phase 4 signal within 30 seconds or remote side hang up
00DA
over 6 seconds
00DB
Can't received any T30 signal within 15 seconds within phase 4
00DC
Received T30 signal in phase 4 other than DCS, DIS or DTC
00DE
Remote side no SUB capability in V34
At phase D, transmitting units out PPS_NULL 3 times consecutivery but
00E0
not answer
00E1
Received incorrect response after sending PPS_NULL signal
00E2
Can't receive any response in RR response procedure after sending PPS_NULL signal
At phase D, transmitting units out PPS_MPS 3 times consecutivery but
00E4
not answer
00E5
Received incorrect response after sending PPS_MPS signal
00E6
Can't receive any response in RR response procedure after sending PPS_MPS signal
00E7
Received DCN after sending PPS_MPS signal
At phase D, transmitting units out PPS_EOP 3 times consecutivery but
00E8
not answer
00E9
Receive PIN signal after sent last page 3 times
00EA
Can't receive any response in RR response procedure after sending PPS_EOP signal
At phase D, transmitting units out EOR_NULL 3 times consecutivery but
00EE
not answer
00EF
Received incorrect response after sending EOR_NULL signal
00F0
Can't receive any response procedure after sending EOR_NULL signal
At phase D, transmitting units out EOR_MPS 3 times consecutivery but
00F1
not answer