Canon L120 Series Service Manual page 130

Hide thumbs Also See for L120 Series:
Table of Contents

Advertisement

Chapter 5
Error Code
0033
0039
001F
003F
0040
0041
0042
0043
0044
0047
0048
004B
004C
004E
004F
0050
0051
0053
0054
0055
0056
0058
005A
005B
005C
005D
005E
005F
0060
0061
0062
0063
0064
0065
0066
0069
0070
0071
0080
0081
0082
0083
0084
0085
0086
0087
0088
008B
008C
008D
008F
0090
0091
0093
0094
0095
5-6
Description
DCN was received through a non-normal procedure
In non-ECM mode, when machine already received the data but next line data
doesn't receive within 13.1 seconds
Can't detect any G3 signal within 35 sec after sending DTC signal
Remote side TSI not define in machine one touch or speed dial directory
Can't receive carrier within 6 sec. after sending CTR signal.
Can't receive carrier within 6 sec. after sending PPR signal.
Can't receive correct signal after sending RNR signal
Fault occurred in the communication procedure signal
Can't receive carrier /FSK signal within 6 sec. after sending MCF signal in ECM mode
Can't receive correct signal after sending ERR signal
Can't receive correct signal after receive PPS_PRI_Q or PRI_Q, EOR_PRI_Q
Can't detect correct FSK signal even through detected FSK tone within 6 sec
Handshake fail during re-train or between page in V.34 Rx
Receive DCN signal after sending DIS signal in V.34
Remote side disconnected after sending ANSam in V.8
Can't receive any correct signal after sending CJ signal in V.8
Can't receive phase 3 signal after phase 2 within 20 seconds in V.34
Modem disconnect after phase 4 in V.34
Remote side disconnect after phase 4 in V.8
Receive incorrect signal after sending DIS signal in V.34
Modem disconnect after sending CFR in V.34
Can't detect image signal within 6 sec after modem enter to primary phase in V.34
Modem cannot detect any correct ECM frame with 3 minutes in phase C
Modem can't detect control channel with 12 sec in phase C
Detect busy tone within control channel after phase C
Modem cannot detect any correct ECM frame with 12 sec in phase C
Can't detect control channel signal after received RCP frame within 6 sec
Can't detect silence after sending JM signal for polling Tx function
There are no any bullietin files to be polled in V34
Machine cannot detect V.21 or V.8 signal with 35 seconds
Modem disconnect in phase D after our side sending out flags sequence
in control channel
Can't receive any flag sequence in control channel within 6 sec in phase D
Can't detect any control channel signal in phase D within 60 seconds even
through energy still on the line
Can't detect any control channel signal within 60 seconds after detect silence
in phase D
Cannot receive signal or carrier after sending CFR in V.34
Capability no match paper size after received is DCS signal
Reception was manually canceled on the machine.
The machine's memory is full.
The recipient's machine did not respond within 35 seconds.
Received DTC signal in transmission phase
Transmitting unit receives a signal other than DIS or DTC. And DCN in phase B
Detected FSK signal, but Can't receive any signal within 35 sec
Detect DCN signal in phase B
Transmitting unit sending DCS 3 times consecutively, but each time responds
with DIS/DTC
Detected responds signal other than DTC, DIS, FTT, DCN or CFR after
sending DCS signal
Training attempt has failed because speed unit can't adjust to low lower speed
Received DCN signal after sending out DCS signal
Receivers protcol of DIS is received, but it is not compatible with our machine
Remote side not support SUB capabillity when relay initiate
The recipient's machine has run out of paper.
Modem not ready to received V.34 data within 6 sec after received CFR signal
Called side document not ready for our polling
Sending out DCS+TCF signal 3 times consecutively but no signal in response
from receiver
Received DCN signal after sending out DCS signal for V34
Time out during transmit ECM frame or RCP command
Wrong ID number when polling Rx or Relay initial

Advertisement

Table of Contents
loading

This manual is also suitable for:

L100 series

Table of Contents