87020-3.book Page 31 Tuesday, March 7, 2006 11:02 AM
Chapter 3: Installation
If the existing cable is too short, please order from the following:
Part No.
E55065
E55066
E55067
E55068
Radome inter-unit cable for use with the C Series display
To display or extension
(power supplied via display unit)

Connecting to an open array

If you are using an open array, this cannot be powered through the display. You will
need to purchase a split pedestal cable or open array package and connect the array
and display as shown:
...for new installations
Note: The power supply for both the display
and the open array must be of the same
voltage and from a common supply source
e.g the same battery or power breaker.
Cable length
Weight
15m
Heavy
25m
Heavy
10m
Light
15m
Light
Open Array
Split pedestal cable
(15 or 25 metres)
Power to open array
Radome power output
2Kw or 4 Kw
2Kw or 4 Kw
2kw
2kw
To Radome Scanner
D6909-1
C-Series Display
PAGE
ACTIVE
WPTS/
MOB
DATA
MENU
OUT
RANGE
IN
OK
CANCEL
Power to display
Boats DC
Power Supply
31