Disassembly and Reassembly
3-21 Base Frame and Feed Roller
1. Before you disassemble the FPC cable you
should remove:
ADF Scanner unit assembly (See page 3-3)
Holder harness (See page 3-16)
Home ass'y (See page 3-19)
2. Unlatch the base frame assembly by pushing the
parts hooked to the main frame using a sharp
tool.
3-22 Line Feed Bracket Assembly
1. Before you disassemble the FPC cable you
should remove:
All covers (See page 3-2, 3-9)
ADF Scanner unit assembly (See page 3-3)
Engine unit (See page 3-15)
ASF unit (See page 3-16)
Holder harness (See page 3-16)
Cartridge assembly (See page 3-18)
Home ass'y (See page 3-19)
Base frame and feed roller (See above)
2. Remove two screws and take out the LF bracket
ass'y from the main frame.
3-20
3. Turn the bearing feed counterclockwise and
take out the base frame and feed roller from
the main frame.