Ember Kit Installation - Drolet ULTRA FLAME DIRECT VENT GAS STOVE Installation And Operating Instructions Manual

Direct vent gas stove
Table of Contents

Advertisement

EMBER KIT INSTALLATION :

Threesmall plastic bags are supplied with your unit. One of the bags contains vermiculite to
simulate ashes in the fire box, another contains lava rock to simulate coals and the last one is
filled with rock wool fibre which, when glowing red, resembles hot embers. (follow instruction
on the next drawing)
1.
Place some vermiculite and some lava rocks at the bottom of the fire box and on top of
the burner plate. Never put to much of these material on the burner. The air must pass
through the burner easily for oxygen supply.
CAUTION : Blocking gas ports with vermiculite or lava rock will result in poor light-up
performance and delayed ignition.
2.
Place five or six pieces of rock wool fibre approximately 1" large on top of the front gas
ports. Place two or three pieces over each of the back gas ports. Make sure not to put too
many pieces as this could result in an altered flame pattern and possible carbondeposition.