REFRACTORY PANELS INSTALLATION:

1.
Remove the glass front assembly.
2.
Remove the logs from the firebox.
3.
Place the back refractory against the back of the firebox.
4.
Install the two side refractory panels by sliding them between the firebox sides and the
baffle plate.
5.
Put the logs back in place.
6.
Install the glass front assembly.

GOLD TRIM INSTALLATION:

Slide both trim pieces from the front over the edges of the stove firebox . Make sure the back end
of each piece is inserted over the T-shaped retainers as shown.
BOTTOM GOLD TRIM
TOP GOLD TRIM
TOP OF FIREBOX
"T" SHAPED RETAINERS
BOTTOM OF FIREBOX