DISTANT INSTALLATION
4)
It is possible to use up to 25 feet of pipe and a wall vent terminal or roof vent terminal ( no
E5700 ) However, the following restrictions must be applied. (see figure, next page)
- Maximum vertical lenght is 10 feet with the wall vent terminal.
- Maximum horizontal lenght is 10 feet
- Number of 45° or 90° elbows is three
• For installation proceed in the same manner as the basement installation.
• The venting distant kit ( No E-5705 ) contain:
- (15 feet)
- (1)
- (2)
- (15 feet)
- (6)
- (24 feet)
- (30)
- (1)
• The following pieces must be supplied by the installer.
- Galvanized or black pipe minimum 24 gauges
- Appropriate roof flashing
- Roof braces ( if required )
• The clearance between the pipe and the combustible wall must be 2" from the pipe additional
radiation shield can be ordered. Part number is E-5710.
5" LOCKING BAND
5" FLEXIBLE FLUE PIPE
4" FOR BASEMENT OR DISTANT
INSTALLATION
of 4" diameter, 2 plys flexible pipe
4" diameter union
locking bands
high temperature insulation
spring spacers
of aluminium tape
metal screws
radiation shield
SCREWS
8"RIGID AIR INLET PIPE
15