Clearance between the stove and any combustible material must also be respected while
installing your appliance. Clearance to the floor is 0".
Clearance between wall and the pipe is 1". Do not install pipe in an enclosed area or through an
insulated wall without a radiation shield ( no E-5710)

INSTALLATION OF THE UNIT

Move the ULTRA FLAME to the desired position. Mark the location for the gas inlet pipe
and the location where the vent pipes will go through the wall. Remove the appliance.
Route a 3/8" minimum NPT iron pipe gas line to the desired location.
Install a shutoff valve to the gas line. Tighten securely using a pipe joint compound.
Install a 1/8" NPT plugged tapping for test gauge connection immediately upstream of the gas
supply connection to the appliance.
If you wish to make a direct electrical connection to the blower without using the six-foot
cord supplied, route a 120 volt, 60 Hz electrical power supply line to the same location.
Remove the power cord and connect the 120V line as per the following procedure :
- Unscrew the speed control unit and pull a few inches away from the junction box
- Unscrew the two marr connectors attached to the cord (P) and the cord ground
- Remove the cord and route the supply line through the same holes
- Make the electrical connection with the same wires the cord was attached to
- Screw the ground wire to the junction box (G)
- Screw the speed control unit back in place