Installation Compliance - Drolet ECO-55 Installation Manual

Hide thumbs Also See for ECO-55:
Table of Contents

Advertisement

Available languages

Available languages

Here is an example to help you calculate Equivalent
Vent Length. On the following figure the EVL can be
calculated like this:
2 feet of horizontal run (2 X 1' EVL) = 2' of EVL
90° elbow or "Tee" (1 X 5' EVL)
12 feet of vertical run
(12' X 0.5' EVL)
Termination cap
Total EVL
Since the total EVL is less than 15 feet, the re-
commended exhaust venting diameter is 3".

4.3.2 INSTALLATION COMPLIANCE

To determine if your installation is compliant, the
exhaust venting system must end within the grid on
the venting system chart. The previous installation
has 2 feet of horizontal run and 12 feet of vertical
run. It is thus standard since the venting system ends
in the gridded area.
CAUTION
Horizontal runs shall not exceed 9 feet.
Never exceed 30 feet of evl.
Page 10
=5' of EVL
TO REDUCE THE RISK OF SMOKE SPILLAGE
= 6' of EVL
THERE SHOULD ALWAYS BE AT LEAST ONE
FOOT OF VERTICAL RISE FOR EACH FOOT OF
= 0' of EVL
HORIZONTAL RUN. IN ALL CASES, AT LEAST 3
FEET OF VERTICAL RISE IS NEEDED.
= 13' of EVL
TERMINATION OF A SIDE WALL VENT SHOULD
BE LOCATED TO AVOID PERSONAL BURN
INJURY, FIRE HAZARD AND INTERFERENCE
WITH
PROPERTIES. EXHAUST GASES CAN REACH
TEMPERATURES OF 500°F (260°C) AND CAUSE
SERIOUS BURNS.
TERMINATION COLLAR (SPARK ARRESTER)
IS MANDATORY AND MUST BE CLEAR OF ANY
DEBRIS AT ALL TIME.
CAUTION
WARNING
OR
DAMAGE
TO
WARNING
INSTALLATION MANUAL ECO-55/ECO-55ST