Drolet SIT 0.820.633 Instruction Manual

Drolet direct vent gas stove instruction manual

Advertisement

Quick Links

ULTRA FLAME
WARNING: If the information in these
instructions is not followed exactly, a fire or
explosion may result causing property
damage, personal injury or loss of life.
FOR YOUR SAFETY: Do not store or use
gasoline or other flammable vapours and
liquids in the vicinity of this or any other
appliance.
Installation and service must be performed
by a qualified installer, service agency or the
gas supplier.
THE INSTALLATION MUST CONFORM WITH LOCAL CODES OR, IN THE ABSENCE
OF LOCAL CODES, WITH THE CURRENT NATIONAL FUEL GAS CODE ANSI Z223.1
(USA) OR THE CURRENT CAN/CGA B149 INSTALLATION CODES (CANADA).
PLEASE KEEP THIS INSTRUCTIONS MANUAL
DIRECT VENT GAS STOVE
INSTRUCTIONS MANUAL

FOR FUTURE REFERENCE

WHAT TO DO IF YOU SMELL GAS:
• Do not try to light any appliance.
• Do not touch any electric switch; do not
use any phone in your building.
• Immediately call your gas supplier from
neighbour's
phone.
supplier's instructions.
• If you cannot reach your gas supplier, call
the fire department.
Follow
the
gas
000920/45046A

Advertisement

Table of Contents
loading

Summary of Contents for Drolet SIT 0.820.633

  • Page 1: For Future Reference

    ULTRA FLAME DIRECT VENT GAS STOVE INSTRUCTIONS MANUAL WARNING: If the information in these instructions is not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life. FOR YOUR SAFETY: Do not store or use...
  • Page 2: Table Of Contents

    ULTRA FLAME DIRECT VENT GAS STOVE GENERAL INFORMATION... 2 WARNING... 2 TECHNICAL SPÉCIFICATIONS ... 3 Dimensions... 3 Burner... 4 Gas Valve SIT 820 Nova mV ... 4 Pressure Adjustments ... 4 Available Wall Venting Kits ... 5 Available Options ... 5 SELECTING TYPICAL INSTALLATION ...
  • Page 3: General Information

    For increased efficiency, we offer as an option a 130 CFM blower. Speed control, thermo-switch and electrical wiring are pre-installed on your stove. Easy to hook up, your fan will therefore turn itself « ON » and « OFF »...
  • Page 4: Technical Spécifications

    915 mm • Note 1 Floor :combustible Note 1 : Your stove has been successfully certified while installed on a wood floor. Do not install your stove on carpet. Choose instead ceramic tile or wood floor. SIDE VIEW 735 mm...
  • Page 5: Burner

    Gas Valve : Your stove is equipped with a sophisticated gas control valve, which will give you a safe use of your appliance. The gas control valve SIT 820 Nova mV operates without electricity due to the energy given by the pilot flame and captured by the thermo-generator.
  • Page 6: Available Wall Venting Kits

    ULTRA FLAME DIRECT VENT GAS STOVE Available Wall Venting Kits Venting Kit for Direct Installation AC05506 DESCRIPTION • Outer pipe (∅ 8 in.) for admission of fuel-air in carbon steel, black 24GA ; • Inner flexible pipe (∅ 5 in.) in aluminum allowing the exhaust of the flue ;...
  • Page 7: Selecting Typical Installation

    Combustible Direct Installation Note 1 :Your stove has been successfully certified while installed on a wood floor. Do not install your stove on carpet. Choose instead ceramic tile or wood floor. Clearance between wall and the pipe is 1". Do not install the vent pipe in an enclosed area or through an...
  • Page 8: Critical Length Of Venting Pipes

    Terminal Vent Location Your Ultra Flame stove vents through a vent terminal installed on the roof or on the outside of any exterior wall of your house. Many restrictions apply to the vent terminal location that should be considered before locating your stove.
  • Page 9: Installation Of Your Stove

    Where do you install the terminal vent in respect with installation code (page 7 and 8) ; Clearances to combustibles (page 6) ; Length of horizontal and vertical runs of venting pipes Now that you have decided where and how to install your stove, you are ready to start: Pedestal cover 1.
  • Page 10: Installation Of Wall Venting Kits

    2. Install temporary a 8 in. section (4) to visualize where the opening to be done thru the wall. Center of the opening should be at about 23 ½ “above the base of the stove; Note: Horizontal run should have a slope of ¼ in per foot.
  • Page 11: Direct Vent Kit For Corner Installation

    Make sure seal is perfect. Tight the locking band 17. Fix the 8 in. pipe to the stove with three metal screws. 18. Fix Seal around the 8 in. pipe to prevent cold air to get into the house.
  • Page 12 Make sure seal is perfect. Tight the locking band 18. Fix the 8 in. pipe to the stove with three metal screws. 19. Fix Seal around the 8 in. pipe to prevent cold air to get into the house.
  • Page 13: Direct Vent Kit For Basement Installation

    ULTRA FLAME DIRECT VENT GAS STOVE Direct Vent Kit for Basement Installation 1. Move the stove to its position; 2. Install temporary section (4) to visualize where the opening to be done thru the wall. Center of the opening should be at about 23 ½ “above the base of the stove;...
  • Page 14 ULTRA FLAME DIRECT VENT GAS STOVE 11. Install the vent casing and the cover in place 12. Seal around the terminal to prevent water leakage into the house 13. Seal around the 8 in. pipe to prevent cold air to get into the house.
  • Page 15: Direct Vent Kit For Floor Installation

    (4) to visualize where the opening is to be done thru the wall. Center of the opening should be at about 23 ½‘’ above the base of the stove; Note: Horizontal run should have a slope of ¼ in per foot.
  • Page 16 Make sure seal is perfect. 17. Fix the 8 in. pipe to the stove with three metal screws. 18. Fix Seal around the 8 in. pipe to prevent cold air to get into the house.
  • Page 17: Gas Piping

    ULTRA FLAME DIRECT VENT GAS STOVE Gas Piping • Move the ULTRA FLAME to the desired position. • Mark the location for the gas inlet pipe and the location where the vent pipes will go through the wall. Remove the appliance.
  • Page 18: Logs Installation

    3. Cover entirely the first row of the front gas ports. You may have more than one piece thick over the same gas port. 4. Light the stove. Modify the configuration of the rock wool on the gas ports until you reach the desired effect.
  • Page 19: Operation Of Your Stove

    • Make sure your stove is in good condition. Verify that the bay window close perfectly, all controls works as per specification. Vents must be in perfect condition. • Make sure your stove has been fabricated in respect with the type of gas you are using. Refer to the rating plate installed on the back of your stove.
  • Page 20: Shut Down Instructions

    The blower control contains a variable speed switch and a thermal switch. When the stove is operating, the thermal switch will turn on at 120° F, allowing the blower to operate. When the stove cools to 90° F, the thermal switch turns off the blower in about 40 minutes. This prevents the blower from operating when the stove is not in use.
  • Page 21: Maintenance Instructions

    TURN OFF THE GAS WITH THE SHUTDOWN VALVE AND DISCONNECT THE ELECTRICAL POWER BEFORE SERVICING THE APPLIANCE. Yearly maintenance • The venting system and the gas stove should be inspected at least once a year. • Remove the front glass and the logs and clean them if necessary. •...
  • Page 22: Burner

    Remove the glass front assembly. Lift out the grate and hearth insert around burner. Unscrew the burner from the bottom of the combustion chamber, • Slide the burner out from the ventury towards left. Get it out from the stove. Burner Installation •...
  • Page 23: Pilot Assembly

    ULTRA FLAME DIRECT VENT GAS STOVE Pilot Assembly OPTIONS DESCRIPTION Millivolt Wall Thermostat Blower Direct Vent Kit Direct Vent Kit Corner Installation Direct Vent Kit Basement Installation Direct Vent Kit Floor Installation REMPLACEMENT PARTS DESCRIPTION 5 logs set Burner (natural gas)
  • Page 24: Limited Warranty

    Any service call related to an improper installation is not covered by this warranty. Returned products are to be shipped prepaid to Drolet Stoves & Fireplaces for investigation. If a product is found to be defective, Drolet Stoves &...

This manual is also suitable for:

Sit 0.820.634Ultra flame

Table of Contents