Blocked Air Intake - State Water Heaters 60120-100250 Service Handbook

Commercial gas high efficiency water heaters
Table of Contents

Advertisement

5. BLOCKED AIR INTAKE

Blocked Air Intake
Fault occurred 2 mins ago
Restriction in air intake. Check
intake pipe and termination for
blockage.
Call a service professional:
Your Company Name Here
(press [DOWN] for more....)
CHANGE
CHECK/ REPAIR:
• Check pipe for restriction or excessive equivalent length.
• See Instruction Manual for pipe size, length and maximum number of elbows.
• Check actual pipe pressure with a manometer during blower operation. See "Pressure Switch Tests" section
on Page 12 thru Page 15 under "Blower Operation Error" on Page 11.
20
BACK
ADVANCED
Servicing should only be performed by a Qualified Service Technician
CAUSES:
• The Blocked Air Intake Switch has detected a
possible restriction in the air intake pipe.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

119300119400119500

Table of Contents