Blocked Exhaust - State Water Heaters 60120-100250 Service Handbook

Commercial gas high efficiency water heaters
Table of Contents

Advertisement

6. BLOCKED EXHAUST

Blocked Exhaust
Fault occurred 2 mins ago
Restriction in exhaust pipe. Check
exhaust pipe and termination for
blockage.
Call a service professional:
Your Company Name Here
(press [DOWN] for more....)
CHANGE
CHECK/ REPAIR:
• Check pipe for restriction or excessive equivalent length.
• See Instruction Manual for pipe size, length and maximum number of elbows.
• Check actual pipe pressure with a manometer during blower operation. See "Pressure Switch Tests" section
on Page 12 thru Page 15 under "Blower Operation Error" on Page 11.
BACK
ADVANCED
Servicing should only be performed by a Qualified Service Technician
CAUSES:
• The Blocked Exhaust Switch has detected a
possible restriction in the exhaust pipe.
21

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

119300119400119500

Table of Contents