CCB CONNECTION IDENTIFICATION

J1 Socket - High Voltage In
PIN #
1
Ground
2
AUX NC
3
AUX NO
4
AUX Common
5
Not Used
6
AUX NO
7
AUX Common
8
Line Voltage
9
Neutral
J5 Socket - Blower Logic (VFD/ Blower)
PIN #
1
24V
2
PWM Signal
3
Not used
4
Blower Speed Feedback
5
Grounding
J6 Socket - 120V Out
PIN #
1
Neutral
2
Line Voltage Out
J9 Socket - Temperature Probe
PIN #
1
ECO
2
Thermistor
3
Thermistor
4
ECO
J12 Socket - Configuration Key
J13 Socket - Display/ AIN
50
Servicing should only be performed by a Qualified Service Technician