Hatteland HT 403XE STD User Manual

Industrial rack computer

Advertisement

Quick Links

User Manual
HT 403XE STD - Industrial Rack Computer
User Manual HT 403XE STD
Jakob Hatteland Display AS
Åmsosen, N-5578 Nedre Vats, Norway
Updated: 17 Mar 2005
Doc Id: INB100012-1 (Rev 5)
Phone: +47 5276 3700, Fax: +47 5276 5444
For models (including different options):
Slim
www.hatteland.com
-A1, -A2
User Manual

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the HT 403XE STD and is the answer not in the manual?

Questions and answers

Summary of Contents for Hatteland HT 403XE STD

  • Page 1 User Manual HT 403XE STD - Industrial Rack Computer User Manual HT 403XE STD Jakob Hatteland Display AS Åmsosen, N-5578 Nedre Vats, Norway Updated: 17 Mar 2005 Doc Id: INB100012-1 (Rev 5) Phone: +47 5276 3700, Fax: +47 5276 5444...
  • Page 2 Information in this manual are copyrighted to the respective owners. All rights are reserved by Jakob Hatteland Display AS. This information may not, in whole or in part, be copied, photocopied, reproduced, translated or reduced to any electronic medium or machine-readable form without the prior written consent of Jakob Hatteland Display AS.
  • Page 3: Table Of Contents

    Serial Number Label Warranty Label Installation Recommendations ..........11 Installation and mounting of computers Cables Physical Overview - HT 403XE STD Pin Assignments - Common Connectors Specifications ................17 Specifications - HT 403XE STD Technical Drawings..............19 Technical Drawings - HT 403XE STD General - Appendix ..............
  • Page 4: Contents Of Package

    1 pcs of User Manual (Slim version) Note: The separate documentation for third party components are available on attached CD. The printed manual only covers specific information for Hatteland products, and not third party components. 1 pcs of configuration, test report and checklist sheets.
  • Page 5: Inb100012-1 (Rev

    General INB100012-1 (Rev 5)
  • Page 7: General

    K N O W L E D G E - Q U A L I T Y - E C O N O M Y Introduction to Jakob Hatteland Display AS Founded in 1987, Jakob Hatteland Display (JHD), based in Norway, offers the widest range of type approved marine monitors, panel computers and type approved marine computers for the worldwide commercial, naval, yacht and cruise market.
  • Page 8: About This Manual

    All the type-approved displays, panel computers and marine computers offer maximum flexibility for customers’ applications. Hatteland Display offers all products with AC or DC power supply, and marine displays and marine panel computers have a fully linear dimmable function for night vision.
  • Page 9: Basic Construction

    Basic Construction Basic Construction Rack Computers Peripheral PCI/AGP cards Mainboard Memory Fans Harddrive CD-ROM & Floppy Chassis Removable Harddrive General INB100012-1 (Rev 5) IND100209-1...
  • Page 10: Product Labels (Example)

    CPU Type Cabinet Version Rack Size (2U,4U etc.) Hatteland Display (manufacturer) Warranty Label If you are to perform service on a unit still under warranty, any warranty will be void if this label is damaged or removed. This label is useally located on the back of the product and near the serial number label.
  • Page 11: Installation Recommendations

    Installation Recommendations Installation and mounting of computers 1. Most of our units are intended for various methods of installation or mounting (rack mounting, panel mounting, bracket mounting, ceiling/wall mounting) 2. Adequate ventilation is a necessary prerequisite for the life of the unit. The air inlet and outlet openings must definitely be kept clear;...
  • Page 12: Physical Overview - Ht 403Xe Std

    Physical Overview - HT 403XE STD Front area of computer Power LED Alarm LED* Fan LED* Harddrive LED Reset Button 2 x 3.5” Bay S1 LED* S2 LED* Air Filter * not connected or in use! Hatch Keylock CD-ROM / 3.5” Bay Floppy Drive / 2.5”...
  • Page 13: Pin Assignments - Common Connectors

    Pin Assignments - Common Connectors Note: Not all connectors may be available on your specific product. This depends on the amount of additional hardware installed from factory, or customized solutions. These pin assignments are for the common connectors used. Pin Assignments - RJ45 10/100 LAN Pin Assignments - RJ45 10/100/1000 GBLAN 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8...
  • Page 14 Pin Assignments - Common Connectors Pin Assignments - 25P Parallel 13 12 11 10 9 8 7 6 5 4 3 2 1 25 24 23 22 21 20 19 18 17 16 15 14 Pin 01 - STROBE This signal indicates to the printer that data at PD7..0 are valid. Pin 02 - DATA0 Parallel data bus from PC board to printer.
  • Page 15 Pin Assignments - Common Connectors (Additional) Note: These pin assignments applies for products with customer specified COM ports (factory setup). These COM ports are configurable on the motherboard located inside the product. Attempting to config these yourselves, will result in warranty void as the main cover would have to be removed. Pin Assignments - 9P Serial COM RS422 Pin Assignments - 9P Serial COM RS485 4 3 2 1...
  • Page 16 INB100012-1 (Rev 5)
  • Page 17: Specifications

    Specifications INB100012-1 (Rev 5)
  • Page 18: Specifications - Ht 403Xe Std

    : APM Ver 1.2 and ACPI 1.0a • Monitoring : CPU/Chassis, fan and temperature supervision Power Specifications: Power Supply Options: • 110VAC/60Hz or 230VAC/50Hz : Model HT 403XE STD A1 (400W Auto Ranging) Power Consumption: • Operating : TBD(TYP) - TBD (MAX) Connector Type: Available Options: •...
  • Page 19: Technical Drawings

    Technical Drawings INB100012-1 (Rev 5)
  • Page 20: Technical Drawings - Ht 403Xe Std

    Technical Drawings - HT 403XE STD INB100012-1 (Rev 5) IND100221-4...
  • Page 21: General - Appendix

    General - Appendix INB100012-1 (Rev 5)
  • Page 22: Basic Trouble-Shooting

    Basic Trouble-shooting COMMON ERRORS: (Applies for Display products and Panel / Maritime / Rack Computers) If for some reason there should be something wrong with the picture quality or no picture present, check the symptoms carefully and try to cure it with the hints below: NO PICTURE / LED BEHAVIOUR: If there is no light at all in the LED at the FRONT, check power cables.
  • Page 23: Testing & Approvals Overview

    DNV - Det Norske Veritas GL - Germanischer Lloyd BV - Bureau Veritas HT 403XE STD* Industrial Rack Computer *If ambient temperature is 0°C or lower, the unit must be preheated for at least one hour before turning on the unit.
  • Page 24: Return Of Goods Information

    Return Of Goods Information Return of goods: (Applies not to warrenty/normal service/repair of products) Before returning goods, please contact your system supplier before sending anything directly to JHD. When you return products after loan, test, evaulation or products subject for credit, you must ensure that all accessories received from our warehouse is returned to JHD.
  • Page 25: Terms

    8) FREIGHT / PACKING / FORWARDING FEE Jakob Hatteland Display AS charge NOK 50 in forwarding fee for orders below NOK 1.000. For orders below NOK 1.000 Jakob Hatteland Supply AS charge freight according to expenses, and NOK 25 for packing. For handling requested beyond ordinary hours NOK 250 is charged.
  • Page 26 Terms 11) RESPONSIBLITY Seller undertake to deliver faultless and functional capable goods according to existing technical specifications. Seller disclaim responsibility for any damage or loss which directly or indirectly may be caused due to failure or defect with the delivered goods, if carelessness from the seller can be limited up to the cost of the goods. The supplier’s responsibility for defects with the supplied goods do not include secondary damage or loss.
  • Page 27 Terms INSTRUCTIONS FOR THE CONSIGNEE 1) CONTROL Control the goods immediately by receipt. Examine the quantity towards the invoice/packinglist/shipping documents. Look for outward defects on the packing which may indicate damage on or loss of contents. Control the container and the seals for any defects.
  • Page 28: Notes

    Notes General - Appendix INB100012-1 (Rev 5) IND100218-1...
  • Page 29: Revision History

    Revision History Rev. Date Notes 28 May 04 First release. 03 Sep 04 General update. 06 Dec 04 General update. 30 Dec 04 General update. Changed from JHT to JHD logo etc. 17 Mar 05 Updated Testing & Type Approval section. General - Appendix INB100012-1 (Rev 5) IND100213-4...
  • Page 32: Contact Information

    Contact Information Main office, Vats / Norway: Jakob Hatteland Display AS Åmsosen N-5578 Nedre Vats Norway Tel: +47 5276 3700 Fax: +47 5276 5444 Sales office, Oslo / Norway: Jakob Hatteland Display AS Gjerdrums vei 12 N-0484 Oslo Norway Tel: +47 5276 3700...

Table of Contents