Martin MAC Viper Profile User Manual page 38

Hide thumbs Also See for MAC Viper Profile:
Table of Contents

Advertisement

Short code
FAN
FAN
FAN
FAN
FBEP
FBET
FOER
FTER
G1ER
G2ER
IRER
LAER
MAER
PAER
PSER
PTCM
PTTC
PUTC
R1ER
R2ER
SHUE
SLER
SSTO
38
Long message and explanation
BASE FAN 2 ERR
Base cooling fan 2 has stopped running. Error cleared when fixture is reset.
BASE FAN 3 ERR
Base cooling fan 3 has stopped running. Error cleared when fixture is reset.
BASE FAN 4 ERR
Base cooling fan 4 (furthest fan to the right) has stopped running. Error cleared when fixture is
reset.
HD M FAN ERR
Head mid cooling fan has stopped running. Lamp is shut down. Error cleared when fixture is
reset.
PAN FBACK ERR
Pan position magnetic indexing system timeout. Fixture is unable to correct pan position (but
pan movement will often still be possible).
TILT FBACK ERR
Tilt position magnetic indexing system timeout. Fixture is unable to correct tilt position (but tilt
movement will often still be possible).
FOCUS ERROR
Focus position electrical indexing system timeout.
FROST ERROR
Frost position electrical indexing system timeout.
GOBO W 1 ERR
Breakup wheel (gobo wheel 1) magnetic position indexing circuit timeout. Lamp strike disabled
to protect gobo bearings.
GOBO W 2 ERR
Aerial wheel (gobo wheel 2) magnetic position indexing circuit timeout. Lamp strike disabled to
protect gobo bearings.
IRIS ERROR
Iris position electrical indexing system timeout.
LAMP ERROR
The lamp is defective, has exploded, is missing, or the lamp cannot restrike after eight attempts.
Pan and tilt are locked. DMX control is disabled. Fixture reset command in control menus is
disabled.
MAGENTA ERROR
Magenta position electrical indexing system timeout.
PAN ERROR
Pan position electrical indexing system timeout.
PAN SENSOR ERROR
Fixture unable to retrieve reliable data from pan position sensor.
P/T SENSOR CAL
Pan/tilt sensors are not calibrated.
PT TEMP CUT OFF
Pan/tilt PCB temperature too high. Thermal cutoff activated. Lamp is shut down, fans set to max.
Error cleared when fixture is reset.
PSU TEMP CUT OFF
PSU temperature too high. Thermal cutoff activated. Lamp is shut down, fans set to max. Error
cleared when fixture is reset.
GOBO W 1 ROT ERR
Breakup wheel (gobo wheel 1) rotation magnetic indexing circuit timeout.
GOBO W 2 ROT ERR
Aerial wheel (gobo wheel 2) rotation magnetic indexing circuit timeout.
SHUTTER ERROR
Shutter position electrical indexing circuit timeout.
SAFETY LOOP
Lamp safety loop circuit activated. Lamp temperature circuit breaker has cut lamp power. Circuit
breaker resets automatically after lamp temperature has returned to normal operating range.
SYSSTATE TIMEOUT
Some part of the system did not startup as expected. This error message is usually followed by
other more descriptive messages. Service intervention required. Fixture control possibly
disabled, depending on nature of error.
Table 4: Error messages