Long message and explanation
CAL DATA Z/F
CDZF
Valid zoom/focus calibration data not detected in EEPROM. Fixture may be unable to read/write
zoom/focus calibration data to EEPROM.
COM ERR CMY
CECM
Communication error between main processor and color mixing circuit. Lamp shut down.
COM ERR EFFECT
CEEF
Communication error between main processor and effects circuit. Lamp shut down.
COM ERR P/T
CEPT
Communication error between main processor and pan/tilt circuit (an error here will also
probably block communication to several other areas).
COM ERR UI
Communication error between main processor and user interface circuit. Power off/on cycle or
CEUI
firmware upload required to clear error. Check connections and wiring. Control panel/display
module may need to be replaced.
COM ERR Z/F
CEZF
Communication error between main processor and zoom/focus circuit. Check connections and
wiring. Lamp shut down.
CMY TEMP CUT OFF
CMTC
Color mixing temperature too high. Lamp is shut down, fans set to max. Error message cleared
when fixture is reset.
FIXTURE COLD
COLD
PCBs are below -20° C (-4° F). Effect operation may be abnormal or disabled due to cold.
CTC ERROR
CTER
CTC position electrical indexing system timeout.
CYAN ERROR
CYER
Cyan position electrical indexing system timeout.
DIMMER ERROR
DIER
Dimmer position electrical indexing system timeout.
EEPROM UI
EEDF
Valid EEPROM not detected in user interface module. Fixture writes default values into the
EEPROM based on the CAN address.
EEPROM Z/F
EEDF
Valid EEPROM not detected in zoom/focus module. Fixture writes default values into the
EEPROM based on the CAN address.
EEPROM PAN/TILT
EEDF
Valid pan/tilt EEPROM not detected. Fixture writes default values to EEPROM based on CAN
address.
EEPROM EFFECT
EEDF
Valid effects EEPROM not detected in projection module. Fixture writes default values to
EEPROM based on CAN address.
EEPROM CMY
EEDF
Valid color mixing EEPROM not detected in projection module. Fixture writes default values to
EEPROM based on CAN address.
EFFECT TEMP CUT OFF
EFTC
Projection module temperature too high. Lamp is shut down, fans set to max. Error cleared
when fixture is reset.
LAMP L FAN ERR
FAN
Left-hand side lamp cooling fan has stopped running. Lamp is shut down. Error cleared when
fixture is reset.
LAMP R FAN ERR
FAN
Right-hand side lamp cooling fan has stopped running. Lamp is shut down. Error cleared when
fixture is reset.
HEAD L FAN ERR
FAN
Left-hand side head cooling fan has stopped running. Lamp is shut down. Error cleared when
fixture is reset.
HEAD R FAN ERR
FAN
Right-hand side head cooling fan has stopped running. Lamp is shut down. Error cleared when
fixture is reset.
BASE FAN 1 ERR
FAN
Base cooling fan 1 (furthest fan to the left) has stopped running. Error cleared when fixture is
reset.
Table 4: Error messages