Diagnostics and Troubleshooting
Error
Error Code /Status
Code
Message
118
A SCSI ID for the following
device was not found:
_devicename_.
119
The wrong SCSI ID was
specified for the following
device: _devicename_.
120
This device has been setup
for the wrong model of
printer: _devicename_.
121
Unable to read STATUS from
device: _devicename_.
122
The selected LUT contains
data that exceeds the limits
of this printer.
201
An error occurred while
trying to allocate memory.
202
The following parameter is
invalid:_parametername:
_parametervalue_.
203
The function is not supported
by the class.
204
This function has not been
implemented.
205
Must enter the following
field:_field_.
301
The following key was not
found _key_.
302
The following grouper was
not found:_grouper_.
303
The call depends on a
current grouper, but the
current grouper has not been
set.
501
An error occurred while
applying the data.
5-22
Possible Cause/Subsystem
SCSI driver not found.
SCSI ID is incorrect.
Device chosen has not been
found.
Unable to see the printer.
Trying to send a 12-bit LUT to a
10-bit printer.
The system is trying to allocate
memory, however, no memory is
available.
An internal error occurred with the
software.
An internal error occurred with the
software.
An internal error occurred with the
software.
The operator left a blank
configuration field.
• An internal error occurred with
the software.
• One of the files was edited
manually and a key was
changed.
• An internal error occurred with
the software.
• One of the files was edited
manually and a grouper was
changed.
An internal error occurred with the
software.
Possible Solution
Reinstall SCSI driver on host
computer.
Set Target SCSI ID to printer SCSI
ID.
Verify device chosen matches the
printer model.
Check SCSI cable connections.
Select a 10-bit LUT file.
Close any unnecessary
applications.
• Restart the application.
• If problem continues, call for
service.
• Restart the application.
• If problem continues, call for
service.
• Restart the application.
• If problem continues, call for
service.
Enter information in the blank
configuration field.
• Restart the application.
• Restore the key to its previous
value.
• If problem continues, call for
service.
• Restart the application.
• Restore the grouper to its
previous value.
• If problem continues, call for
service.
• Restart the application.
• If problem continues, call for
service.