Set Tilt Cal

Set Tilt Calibration (Set Tilt Cal) menu under the Fixture -> Service menu. This improves the
centering calibration of the tilt parameter. When software 01/16/15 or later is installed, the tilt values
may differ from previous values. Show data can be updated to correct for the update, however for the
best performance users are advised to calibrate the tilt using the luminaire's LCD menu.
To Set Tilt Cal:
Step 1. Press [UP] / [DOWN] arrows until Service appears. Press [OK].
Step 2. Press [UP] / [DOWN] arrows until Set Tilt Cal appears. Press [OK].
Step 3. The display will read Set Tilt Encoder Center Tilt Position Press OK and the
tilt motors will disengage.
Step 4. Manually move by hand the tilt of the luminaire's head until it is in alignment with the yoke
arm as shown in
Step 5. Press [OK] to accept the calibration or [ESC] to cancel the calibration.