6. TROUBLESHOOTING

To troubleshoot the unit, please note the error code displayed on the main unit and review
"Understanding the Error Codes" in section 4.
Problem
No output
voltage. And
Status LED is
off.
No AC output.
Status LED is
Green
No Output.
Status LED is
in Amber

7. SPECIFICATIONS

Note: Specifications are subject to change without notices.
Inverter
AC Output Power
AC Output Current
AC Surge Power (Peak)
AC Output Voltage/Frequency
AC Output Waveform
Nominal DC Input Voltage
No Load battery draw
DC Input Voltage operating range
Under Voltage Alarm
Under Voltage Alarm Recovery
Under Voltage Shutdown
Under Voltage Recovery
Over Voltage Shutdown
USB
USB Port
AC Transfer Switch
Transfer Time
Transfer Relay Rating
AC Input Source Setting
AC Output Port 1 (HW Connector)
AC Output Port 2 (HW Connector, GFCI, CB)
AC Output Port 3 (GFCI & CB)
Display
Display Panel Port
Inverter Mode
Charger Mode
Charger
Charging Voltage Range
Float Voltage Range
Charger Current (max)
Charger Current Setting
Symptom
The unit is off
No power to unit
GFCI is tripped
GFCI is tripped
Check error code on display
Check AC Load Sense setting
Specification
Page 14
Solution
Turn unit ON by following the instruction in
Section 4 to turn unit ON
Check DC fuse, Disconnect switch (if
installed) and check if Branch breaker is
either blown or turned OFF
Check load and reset the GFCI
Check load and reset the GFCI
Verify the error condition and make
correction
AC Load connected must be below the AC
Load sense setting
38326
2000W
16.6A
4000W
120 VAC / 60 Hz
Sinewave (<3% THD)
12.5 VDC
< 1.5 ADC
10.5 – 15.5 VDC
11.0/12.1 VDC
11.3/12.3 VDC
10.5/11.8 VDC
12.0/12.6 VDC
15.5 VDC
5V, 750 mA
< 30 ms
30A
15, 20, 30A
30A
20A
20A
RJ12
Input Voltage, Output Power
Status & Battery voltage
13.5 -14.4 VDC
13.4 – 13.8 VDC
55 ADC
5,15,35,55