Troubleshooting - Nature Power 37002 User Manual

2000 watt power inverter
Table of Contents

Advertisement

TROUBLESHOOTING

PROBLEM
Low or no output
voltage.
Red LED is lit.
Device does not
operate properly
to the inverter.
POSSIBLE CAUSE
Poor contact at terminals OVP/
OLP.
Using incorrect type of voltmeter
to test output voltage.
The battery voltage is below 10
volts.
The equipment being operated is
drawing too much power.
The inverter is too hot (thermal
shutdown).
The inverter may not have
the required capacity to operate
the device.
Page 11 of 14
SOLUTION
Disconnect and reconnect the 12V
connections.
Use a true RMS reading meter.
Recharge or replace the battery.
Use a higher capacity inverter or
decrease the load or device on the
inverter
Allow inverter to cool. Check for
adequate ventilation. Reduce the
load on the inverter to the rated
continuous power output.
Turn the inverter switch OFF and
ON, to reset the inverter.

Advertisement