AC Load on Power Inverter
Although the Power Inverter can provide high surge power up to two times the rated output
power, some appliances may still trigger on the inverter protection system. A higher power
inverter is required for those appliances.
For 38204 , with modified sine wave output, some appliances like speed controllers found in
some fans, power tools and some power tools' AC charger may not like the modified sine wave
generated by the inverter, those appliances may not work or may be damaged if they are
connected to the inverter. If you are unsure about powering any device with the inverter, contact
the manufacturer of the device.
Estimate Run time on Load
Following run time is an estimate based on using a 12V-120AH battery bank for reference.
Actual run time may vary.
Cordless Phone
Clock/Radio
Table Lamp
Freezer (8.8 cu. ft.)
20" LCD TV
Sump Pump (1/2 hp)

5. TROUBLESHOOTING

To trouble shoot the unit, please note the error code display on the main unit and review the
"Understanding the Error Codes" in section 4.
Problem
No AC output and
'Power' indicator is off.
No AC output. 'Fault'
indicator is ON
Products connected to
unit malfunction or
overheat (38204 )
No AC output. 'Power'
indicator is ON (38304
only)
Load
Symptom
The unit is off
No power to inverter
Unit detect fault and has
shutdown
Products connected to unit do
not accept modified sine wave
output generated by the
inverter
GFCI was tripped
Consumption
5W
8W
40W/60W
80W
100W
350W
Turn unit ON using the toggle switch
Check fuse or the Disconnect switch (if
installed) is either blown or turn OFF
Verify the error condition and make correction
and reset unit
Products are not compatible with the modified
sine wave output generated by inverter. See
"AC Load on Power Inverter" in Section 4. Use
NATURE POWER Inverter with sine wave
output
Check load. Reset the GFCI by pressing the
reset button on the GFCI
Page 6 of 8
Estimate Run time
150 hrs
100 hrs
27 hrs/ 18 hrs
15 hrs
11.5 hrs
Not applicable (surge too high)