Connection Of Several Wire Feed Units; Overheating Protection; Water Flow Guard; Remote Control Unit - ESAB AristoMig 320 Instruction Manual

Table of Contents

Advertisement

GB
6.2

Connection of several wire feed units

The wire feed unit AristoFeed 30--4 or AristoFeed 48--4 with control panel (M0) and the
AristoPendant U8 control unit are to be used when connecting several wire feed units.
Please contact authorised ESAB service personnel when connecting several wire feed
units.
6.3

Overheating protection

The power source is fan cooled and is fitted with a thermal cut--out that trips when
the temperature is too high, this prevents overheating. Resetting takes place
automatically once the power source has cooled.
When this occurs the welding current is interrupted and the orange indicating lamp
on the front of the power source comes on.
6.4

Water flow guard

The water flow guard blocks the power source if the cooling water stops. When this
occurs the welding current is interrupted and an alarm is shown on the control unit.
The water flow guard is an accessory.
6.5

Remote control unit

The program version in AristoPendant U8 should be 1.20 or higher. Aristo mchines
with intergral control panels should have program version 1.21 or higher, in order for
the remote control to function correctly.
When the remote control unit is connected, the power source and wire feed unit are
in remote control mode; the buttons and knobs are blocked. The functions can only
be adjusted via the remote unit.
If the remote control unit is not to be used, the remote control unit must be
disconnected from the power source / wire feed unit, as otherwise it will remain in
remote control mode.
When a remote control unit can set the voltage, the function will change to set the
current with MMA welding.
For more information about the operation of the remote control unit, see the
instruction manuals for the control unit/MMC.
7

MAINTENANCE

Regular maintenance is important for safe, reliable operation.
Note!
All guarantee undertakings from the supplier cease to apply if the customer himself
attempts any work in the product during the guarantee period in order to rectify any
faults.
Only those persons who have appropriate electrical knowledge (authorized
personnel) may remove the safety plates to connect or carry out service,
maintenance or repair work on welding equipment.