3. Flange Back Adjustment
(Using Flange Back Adjustment Chart and Subject
More Than 500m Away)
The inner focus lens flange back adjustment is carried out
automatically. In whichever case, the focus will be deviated during
auto focusing/manual focusing.

3-1. Flange Back Adjustment (1)

Subject
Measuring Instrument
Adjustment Page
Adjustment Address
Note1: Check that the data of page: 6, address: 02 is "00". If not, to page:
6, address: 01, set data: 00, and press the PAUSE button.
Note2: Make the lens horizontal and perform this adjustment.
Note3: 1/4 CCD model: CCD-TRV308/TRV408/TRV608
1/6 CCD model: CCD-TRV107/TRV108
Switch setting:
NIGHT SHOT (Lens block) ............................................ OFF
Adjusting method for 1/4 CCD model:
Order Page Address Data
1
0
01
2
F
86
3
F
86
4
6
01
5
6
01
6
6
02
7
F
86
Note4: The adjustment data will be automatically input to page: F, address:
46 to 55, 58.
Adjusting method for 1/6 CCD model:
Order Page Address Data
1
0
01
2
6
01
3
6
01
4
6
02
Note4: The adjustment data will be automatically input to page: F, address:
46 to 55, 58.
Processing after Completing Adjustments:
Order Page Address Data
1
6
01
2
3
Flange back adjustment chart
(2.0 m from the front of the protection
glass)
(Luminance: 200 ± 30 lux)
Adjustment remote commander
F
46 to 55, 58
Procedure
01
Set the data.
Write down the data.
00
Set the data and press PAUSE
button.
13
Set the data, and press PAUSE
button.
15
Set the data, and press PAUSE
button.
Check that the data changes to
"01". (Note4)
Set the data that is written down
at step 2 and press PAUSE button.
Procedure
01
Set the data.
13
Set the data, and press PAUSE
button.
15
Set the data, and press PAUSE
button.
Check that the data changes to
"01". (Note4)
Procedure
00
Set the data, and press PAUSE
button.
Turn off the power and turn on
again.
Perform "Flange Back Adjustment
(2)"

3-2. Flange Back Adjustment (2)

Perform this adjustment after performing "Flange Back Adjustment
(1)".
Subject
Measurement Point
Measuring Instrument
Adjustment Page
Adjustment Address
Note1: Check that the data of page: 6, address: 02 is "00". If not, to page:
6, address: 01, set data: 00, and press the PAUSE button.
Note2: Make the lens horizontal and perform this adjustment.
Switch setting:
NIGHT SHOT (Lens block) ............................................ OFF
Preparations:
1) Set the zoom lens to the TELE end and expose a subject that is
more than 500m away (subject with clear contrast such as
building, etc.). (Nearby subjects less than 500m away should
not be in the screen.)
Adjusting method for 1/4 CCD model:
Order Page Address Data
1
0
01
2
F
86
3
F
86
4
6
01
5
6
6
01
7
6
02
8
F
86
Note3: The adjustment data will be automatically input to page: F, address:
46 to 55, 58.
Adjusting method for 1/6 CCD model:
Order Page Address Data
1
0
01
2
6
01
3
4
6
01
5
6
02
Note3: The adjustment data will be automatically input to page: F, address:
46 to 55, 58.
Processing after Completing Adjustments:
Order Page Address Data
1
6
01
2
0
01
3
4
5-14
Subject more than 500m away
(Subjects with clear contrast such as
buildings, etc.)
Check operation on TV monitor
F
46 to 55, 58
Procedure
01
Set the data.
Write down the data.
00
Set the data and press PAUSE button.
13
Set the data, and press PAUSE button.
Place a ND filter on the lens so
that the optimum image is obtain.
29
Set the data, and press PAUSE button.
Check that the data changes to
"01". (Note3)
Set the data that is written down
at step 2 and press PAUSE button.
Procedure
01
Set the data.
13
Set the data, and press PAUSE button.
Place a ND filter on the lens so
that the optimum image is obtain.
29
Set the data, and press PAUSE button.
Check that the data changes to
"01". (Note3)
Procedure
00
Set the data, and press PAUSE button.
00
Set the data.
Turn off the power and turn on again.