1-1-2.

Preparations

Note1: For details of how remove the cabinet and boards, refer to "2.
DISASSEMBLY".
Note2: When performing only the adjustments, the lens block and boards
need not be disassembled.
1)
Connect the equipment for adjustments according to Fig. 5-1-4.
2)
Connect the adjustment remote commander to CN713 of VC-
272 board via CPC jig for SB (J-6082-539-A). To operate the
adjustment remote commander, connect the AC power adapter
to the DC IN jack of CPC jig for SB, or connect the L series
Info-LITHIUM battery to the battery terminal of CPC jig for
SB. (Fig. 5-1-3.)
3)
The front panel block (SI-033 board, microphone unit, video
light) need not be assembled except during the steady shot
operation check.
Note3: As removing the cabinet (R) (removing the VC-272 board CN709)
means removing the lithium 3V power supply (CF-2000 block
BT001), data such as date, time, user-set menus will be lost. After
completing adjustments, reset these data. If the cabinet (R) has
been removed, the self-diagnosis data, data on history of use (total
drum rotation time etc.) will be lost. Before removing, note down
the self-diagnosis data (data of page: 2, address: B0 to C6) and
data on history use (data of page: 2, address: A2 to AA and E0 to
E2). (Refer to "5-4. Service Mode" for the self-diagnosis data and
data on the history use.)
Note4: Setting the "Forced Camera Power ON" Mode
1) Select page: 0, address: 01, and set data: 01.
2) Select page: D, address: 10, set data: 01, and press the PAUSE
button.
The above procedure will enable the camera power to be turned
on with the SS-2000 block removed. After completing adjustments,
be sure to exit the "Forced Camera Power ON Mode".
Note5: Exiting the "Forced Camera Power ON" Mode
1) Select page: 0, address: 01, and set data: 01.
2) Select page: D, address: 10, set data: 00, and press the PAUSE
button.
3) Select page: 0, address: 01, and set data: 00.
CCD-TRV107/TRV108/TRV308/TRV408/TRV608
Pattern box
Front of the lens
Remove the CPC lid
5-5
1.5 m
Fig. 5-1-2.
CPC connector
16
CN713
CPC jig
1
Conductor side
Fig. 5-1-3.